Two quotations can both say "24-fiber outdoor cable" and still describe different products. One may include steel-tape armor, a defined water-blocking system and project-specific test records. The other may leave those items open. Comparing the two prices before those differences are settled tells you very little about which supplier is cheaper.
This guide covers the step between an approved cable design and a purchase order: how to write the specification, how to compare quotations on the same basis, which evidence to request from a supplier, and how to confirm samples, tests and delivery dates. It is written for ISPs, FTTH operators, contractors and procurement teams buying finished cable for network projects.
Quick answer: Fix one approved cable configuration first. Send every supplier the same RFQ fields. Ask for the price unit, validity date and cost scope in writing, and request model-specific documents that can be traced to reel or lot numbers. Compare prices after the differences between quotes have been cleared.
Define the Cable You Are Buying
Start with the route and the approved configuration, then ask for prices. Record where the cable will run (duct, direct burial, aerial span, building riser, or a transition between them), the fiber grade and count, and the cable construction your project engineer approved. A 24-fiber cable for a duct route and one for an aerial span can differ in strength members, armor, jacket and outer diameter even though the fiber count matches.
How to arrive at that configuration is covered in our 8-step guide to choosing fiber optic cable. This guide begins where that one ends, when the approved design goes out for quotation.
Two Glory Optical product pages show how much detail sits inside a single cable family:
Official Glory product illustration. |
GYXTS outdoor cableThe product page describes a central loose tube in high-modulus plastic, a waterproof compound inside the tube, corrugated steel tape armor and a UV-resistant polyethylene sheath. An RFQ for this family still needs the fiber grade, core count and the controlled drawing revision. View GYXTS cable |
Official Glory product illustration. |
FTTH flat drop cableThe product page describes a flat drop cable with parallel FRP strength members, a loose-tube fiber unit and an outer PE sheath. Confirm the approved fiber grade, fiber count, dimensions and drawing revision before ordering. View FTTH drop cable |
Browse the full ranges for FTTH cable, indoor fiber optic cables and outdoor cable.
Specifications to Put in a Fiber Cable RFQ
Keep fiber grade, cable construction and installation requirements as separate fields. A fiber designation leaves the jacket, strength system, armor and installation limits of the finished cable undefined, so each needs its own line.
| Field group | What to state in the RFQ |
|---|---|
| Fiber | Exact category and subcategory (for example G.652.D or G.657.A2), fiber count, working and spare fibers, color code. ITU-T G.652 covers single-mode fiber and cable characteristics; ITU-T G.657 covers bend-loss-insensitive single-mode fiber. Confirm the subcategory and the finished cable model together. |
| Construction | Controlled drawing and revision: loose tube or tight buffer, strength members, armor, water-blocking, outer diameter and weight. IEC 60794-1-1:2023 sets general requirements for optical cables, including transmission, materials, mechanical and environmental characteristics. Name the applicable IEC 60794 part, edition, test methods and acceptance criteria instead of writing "IEC compliant". |
| Jacket | Record the jacket material, the smoke and halogen requirements, and any building-use rating as three separate items. UL evaluates low smoke and halogen-free performance as two distinct aspects, and UL 1651 separates OFNP, OFNR and the conductive-element types OFCP and OFCR. Name the region where the cable will be installed and ask for the matching documents. |
| Mechanical | Pulling tension, crush, installation and long-term bend radius, temperature range. The FOA gives 20× cable diameter under tension and 10× with no load as typical values, and notes that some cables carry different ratings. Use the limits in the model's own datasheet. ADSS cable also needs span and load design inputs. |
| Optical | Test wavelengths, measurement method, acceptance limits, and how results map to reel or lot numbers. If the contract cites ANSI/TIA-568.3, name the edition: TIA announced 568.3-E on 29 September 2022, revising 568.3-D. |
| Reels and packaging | Total length, reel length and tolerance, whether splices within a reel are acceptable, reel type, end protection, printing, reel numbering, package size and weight. |
| Pre-terminated assemblies | Quote as a complete assembly: end connectors, length reference points, branches, polarity, polish, male or female pinning, and the scope of tests. For MPO/MTP assemblies, see the MTP/MPO range. |
Compare Price Units and Quotation Scope
Suppliers quote in different units, and the unit alone can make two offers look far apart. This guide gives no per-meter price list on purpose: a figure only means something when its configuration, quantity, date and commercial scope are defined. Ask each supplier to state those items on the quotation itself.
| Comparison field | What the supplier should state |
|---|---|
| Price unit | USD per finished-cable meter, per finished-cable km, per reel, or per complete pre-terminated assembly. Keep one unit across all quotes. |
| Quantity and reels | Total finished length, length per reel, number of reels, length tolerance, and whether splices are accepted. |
| Commercial scope | Currency, validity date, payment terms, trade term with named place, packing and document charges. |
| Logistics scope | Freight, insurance, destination charges, taxes, customs clearance and inland transport, with the responsible party for each. |
| Delivery commitment | Sample and drawing approval, material and capacity confirmation, production, ready-for-collection date, estimated transport, target site arrival. |
A few unit checks save time. Four reels of 2 km each make 8 km of finished cable. If that cable has 24 fibers, it contains 192 fiber-km (8 km × 24), which measures fiber length. A price per fiber-km for bare fiber is a different quantity from the price of finished cable. When one quote is per meter and another per foot, multiply the per-meter price by 0.3048 to get the per-foot price, after confirming that both describe the same construction and the same scope.
For trade terms, the ICC publishes an Incoterms 2020 checklist that shows how delivery places and responsibilities change from one rule to another. Record the rule, its edition and the named place, then list freight, insurance and import costs separately so the landed cost of each quote can be compared.
Check the Supplier and the Evidence
Review the supplier at three levels: the company, the product model and the delivered batch. Each level has its own documents. Judge capability from those documents, since a fast reply to an inquiry says little about who manufactures the cable.
| Level | Documents to request | What the document shows |
|---|---|---|
| Company | Contracting entity, manufacturing address, process description and traceability method. | Who signs the contract and where the cable is made. |
| Management system | Certificate holder, scope, validity status and issuing body. | How the organization manages quality. |
| Product identity | Model number, controlled datasheet, cross-section drawing, revision and material list. | Which exact cable is being offered. |
| Test records | Sample or model identification, method, conditions, results, date and testing party. | Which fiber counts, materials and constructions each report covers. |
| Batch delivery | Order number, lot numbers, reel numbers and shipped test data linked to each other. | That the reels on site match the records. |
| Approved sample | A sample built to the production configuration, with inspection items and tolerances. | The reference that production reels are checked against. |
On the management-system layer, ISO 9001 addresses an organization's quality management system, and certification is carried out by independent certification bodies. Check the certificate holder, the scope and the current status on the document that applies to your supplier. Performance of a particular cable model comes from that model's own test records.
Example: Two Quotes for a 24-Fiber Cable
The example below is an illustration for teaching purposes. It is not a Glory Optical customer project and contains no real prices. Suppose a project approved this configuration: 24F G.652.D, outdoor duct route, water-blocking construction, steel-tape armor, PE jacket, 4 reels of 2 km each. Exact diameter, mechanical and optical limits come from a controlled drawing.
| Item | Supplier A | Supplier B | Buyer action |
|---|---|---|---|
| 24F G.652.D | Confirmed | Confirmed | Matching fiber grade is only the first of several items to align. |
| Steel-tape armor | Per drawing | Armor not listed | Ask B whether armor is omitted or simply unmentioned. |
| Jacket and water-blocking | Approved configuration | "Outdoor use" | Request the exact materials and structure. |
| Reel length | 4 × 2 km | 8 × 1 km | Different splicing and installation plans; ask engineering to confirm. |
| Test documents | Identity and scope stated | "Tested" | Request traceable records and the agreed test scope. |
| Cost scope | Named place and rule | Unit price only | Compare totals after cost scope is aligned. |
The purpose of the exercise is a revised quotation from each supplier on one configuration. Price comparison starts once Supplier B has confirmed the armor, materials, reel plan, test files and cost scope.
Agree Samples, Testing and Reel Identification
Approve a sample that matches the production configuration. Record the inspection items and allowed tolerances, and keep a reference to the approved sample in the order file. Color and feel give a quick visual check. Fire performance, ageing behavior and mechanical limits come from test methods and their results.
The FOA 2025 installation standard treats insertion loss testing, OTDR testing and documentation as separate subjects (see Section 12 and Appendix B). Mirror that separation in the order. State the test method, the wavelength, the scope (every fiber or an agreed sample), the acceptance limit and the record format. A single OTDR trace covers one measurement, so the order should list each test that applies.
Keep factory tests and installed-link tests under separate headings. Factory reel records describe the product leaving the plant; installed-link tests describe the finished route after pulling, splicing and termination. Tie each record to a reel number or lot number so the reel on the drum can be matched to the paper.
Bend radius gives a concrete case. If a model's datasheet adopts the 20× and 10× rule, a 10 mm cable has an installation bend radius of 200 mm and a long-term radius of 100 mm. Write these numbers into the construction drawings only when the model's own document states that rule; fiber-level bend capability does not set the limit for the finished cable. Inspection frequency and sample size are project-specific contract items, so agree them for the order itself.
Confirm Quote Validity and Delivery Milestones
Ask for an expiry date on the quotation, written as a calendar date, and a clear starting condition for production lead time. Sample approval, drawing approval, material availability and payment can each affect when the clock starts. Then split the delivery into milestones:
- Supply status confirmed (date)
- Sample and drawing approved (date)
- Production start condition met (condition and date)
- Ready for collection (date)
- Estimated transport time and responsible party for each stage
- Target arrival at site (date)
For split deliveries, list quantities and documents for each shipment. For additional context on dated supply evidence and procurement planning, see our FTTH fiber supply and lead-time analysis.
Send a Complete RFQ to Glory Optical
A complete RFQ lets a supplier quote once, with fewer clarification rounds. Copy this list into your inquiry and attach the datasheet or drawing:
| Group | Fields |
|---|---|
| Project | Application, region, installation route (duct, direct burial, aerial, indoor) and environment transitions. |
| Cable | Fiber grade and count, controlled drawing with revision, jacket and fire requirements, mechanical limits, test wavelengths and acceptance limits. |
| Quantity | Total length, reel length and tolerance, splice policy, reel type, printing and package requirements. |
| Documents | Datasheet, cross-section, compliance documents, batch test reports and any project-specific files. |
| Commercial | Currency, price unit, validity date, payment terms, trade term with edition and named place, listed deviations and exclusions. |
| Delivery | Production start condition, ready-for-collection date, destination and target site arrival date. |
| Change control | No change to fiber, construction, materials, tests or marking without written approval; substitutions quoted separately. |
Send Glory Optical your route, fiber grade and count, approved cable construction, quantity, reel plan and required delivery location. Include the datasheet or drawing and any project-specific documentation requirements. Request a configuration-specific quotation with its validity date, proposed schedule and clearly stated deviations.
Glory's OEM page lists FTTH drop, indoor, outdoor, ROC drop and ADSS cable families, and lists reel length and cable printing among the options to discuss per project. Availability, schedule and documents are confirmed for each configuration in the quotation.
Frequently Asked Questions
What information should I send with a fiber cable RFQ?
Send the installation route, fiber grade and count, the approved construction with its datasheet or drawing revision, the quantity and reel plan, jacket and fire requirements for your region, test and document requirements, the delivery location with trade term, and your target dates. A complete first inquiry shortens the number of clarification rounds.
Why can two quotes for a 24-fiber cable differ so much?
The usual causes are different armor, water-blocking, strength members, jacket material and outer diameter, along with different reel plans, test scope, price units and trade-term scope. Ask both suppliers to confirm each item against one drawing, then compare the revised quotes.
Does an ISO 9001 certificate prove the cable meets my specification?
The certificate relates to the supplier's quality management system within its stated scope. For your specification, request the model's controlled datasheet, test records tied to that model, and batch documents tied to your reels. Check the certificate holder, scope and validity as well.
What should be agreed before approving a cable sample?
Confirm that the sample matches the production configuration, list the inspection items and tolerances, record any deviations in writing, and keep an approved reference sample. Also agree the test method and the record format that will accompany production reels.
How should I confirm quote validity and delivery dates?
Ask for a calendar expiry date and the condition that starts production lead time. Request separate dates for sample approval, ready for collection, shipping and site arrival, and per-shipment quantities if the order is split.
Sources
- ITU-T G.652 (08/2024)
- ITU-T G.657 (2024 edition summary)
- IEC 60794-1-1:2023 (scope)
- TIA: ANSI/TIA-568.3-E announcement, 29 September 2022
- UL: low smoke and halogen-free cable certification
- UL 1651 (scope, 2023 revision)
- FOA: bend radius
- FOA: Installation Standard 2025 V1
- ISO 9001 explained; ISO/CASCO attestations of conformity
- ICC: Incoterms 2020 checklist (2024 update)