LC OM4 DX High-Low Fiber Optic Adapter

Send Inquiry
LC OM4 DX High-Low Fiber Optic Adapter
Details
The LC OM4 DX High-Low Adapter is a violet, flange-free duplex LC coupler for multimode PC connections in high-density patch panels, ODF trays and equipment-room cross-connects. Its ceramic alignment sleeve, ≤0.2 dB insertion loss, >1,000-mating-cycle durability and −40°C to +85°C working range provide a serviceable LC-to-LC interface for OM4 patch cords and pigtails. Confirm the panel cutout and required high-low duplex footprint before ordering.
Category
Fiber Optic Adapter
Share to
Description

Product overview

Violet LC OM4 Duplex Adapter for Panel Cross-Connections

This adapter creates a passive alignment point between two LC multimode connectors. The duplex high-low body presents two channels in an offset arrangement, while the ceramic sleeve aligns the connector ferrules inside patch panels, optical distribution frames, equipment faceplates and premise cabling cross-connects.

Network function

The adapter joins two LC multimode PC connectors without splicing or changing the fiber type. It can connect equipment-side OM4 patch cords to panel-side patch cords or pigtails at a serviceable passive interface in LAN, WAN, telecom, video-transmission, CATV and FTTx cabling paths.

Product-specific configuration

The standard configuration combines an LC interface, duplex high-low body, PC polish, multimode use, violet housing, ceramic alignment sleeve and mounting without a flange. Optical and mechanical criteria include ≤0.2 dB insertion loss, more than 1,000 mating cycles and RoHS-compliant status.

What the adapter does-and does not do

The LC OM4 DX High-Low Adapter mechanically aligns two compatible LC multimode connectors. It does not convert singlemode to multimode, change connector polish, increase fiber bandwidth or replace the need to clean and inspect connector end faces before final mating.

Violet LC OM4 DX high-low duplex adapter product view one
LC OM4 DX high-low flangeless adapter product view two
LC OM4 duplex multimode adapter product view three

Product selling points

LC OM4 DX High-Low Adapter Features

Each feature below addresses a separate panel-layout, optical-performance, maintenance or procurement decision.

Duplex High-Low LC Geometry

The body combines two LC channels in a high-low arrangement instead of a simplex or high-high format. Matching this footprint to the panel drawing prevents a mechanically incorrect adapter from reaching assembly and lets panel builders maintain the intended duplex port layout.

≤0.2 dB Insertion Loss

Insertion loss is specified at no higher than 0.2 dB for the adapter. This gives designers a defined passive-connection value to review within the channel loss budget, while the RFQ should state the test method, reference cords and acceptance record required for the finished order.

Ceramic Alignment Sleeve

A ceramic sleeve centers the two mating LC ferrules inside each adapter channel. Compared with treating the coupler as a color-only accessory, specifying the sleeve material gives procurement and incoming inspection a concrete component to verify in repeated panel builds.

>1,000-Mating-Cycle Durability

The adapter supports more than 1,000 mating cycles, with optical change after 1,000 insertions below 0.2 dB. That durability criterion is relevant to patching fields and test points where links are disconnected during moves, adds, equipment replacement or troubleshooting.

Violet OM4 Port Identification

The violet housing distinguishes this OM4-designated adapter from the aqua OM3, beige general-multimode and blue or green singlemode variants listed in adjacent adapter families. A consistent color schedule helps technicians trace the intended cabling category in mixed patch panels.

Flange-Free Panel Mounting

The housing is specified without a flange and operates from −40°C to +85°C. The low-profile mounting format suits compatible panel openings where front flanges are not required; buyers should submit the panel cutout and retention details for fit confirmation.

 

Product configuration

Standard LC OM4 Adapter Configuration and Related Choices

The standard product is a violet OM4 multimode duplex high-low configuration. Other body styles, colors, polish types and fiber modes are separate adapter products and should not be substituted without checking the panel and cabling specification.

Product identifierLC OM4 DX High-Low Adapter. Add the buyer's project part number to the drawing, label and packing record when required.
Optical interfaceLC multimode, PC polish, duplex connection.
Body and mountingHigh-low duplex body without flange; panel cutout and retention method require drawing confirmation.
Alignment componentCeramic alignment sleeve.
IdentificationViolet housing for the OM4-designated version.
Related separate productsLC OM3 DX high-low, LC MM DX high-low, LC UPC DX high-low and LC OM4 simplex without-flange versions are available as separate selections.
Project-defined fieldsPanel cutout, exact dimensions, retention hardware, inspection plan, labels, logo, packaging and requested test records.

Adapter Family Selection Table

Separate Product Body Style Polish Fiber Mode / Designation Housing Color Use When
LC OM4 DX High-Low Adapter Duplex high-low PC Multimode / OM4 Violet The BOM and panel drawing call for the OM4 high-low duplex version.
LC OM3 DX High-Low Adapter Duplex high-low PC Multimode / OM3 Aqua The patching field is identified and documented as OM3.
LC MM DX High-Low Adapter Duplex high-low PC Multimode Beige The project uses the standard multimode version rather than an OM3/OM4 color designation.
LC OM4 SX Adapter Without Flange Simplex PC Multimode / OM4 Confirm on RFQ Only one LC channel is required and the panel opening is for a simplex adapter.

Related products use different fiber, polish, color or body configurations. Do not substitute them without confirming the panel and cabling BOM.

 

Technical data

LC OM4 DX High-Low Adapter Technical Specifications

The tables separate the general, optical, mechanical, compatibility and ordering requirements needed for product selection and project purchasing.

General Technical Specifications

Interface, body, material, temperature and compliance data.

Item Specification Selection Note
Product name LC OM4 DX High-Low Adapter Use this identifier with an approved image, drawing or buyer-specific project part number.
Product family Fiber optic adapter / coupler Passive LC-to-LC connector alignment point.
Adapter interface LC Use with compatible LC connectorized patch cords or pigtails.
Body style Duplex high-low Two LC channels; confirm the exact panel footprint.
Connector polish type PC Use a separate APC adapter configuration when APC connectors are required.
Connector fiber mode Multimode The product name identifies the version as OM4.
Alignment sleeve material Ceramic Centers the mating LC ferrules.
Housing color Violet Use consistently with the approved project color schedule.
Mounting type Without flange Panel dimensions and retention details must be confirmed by drawing or sample.
Working temperature −40°C to +85°C Product operating range; installation conditions must be specified separately.
Storage temperature −40°C to +85°C Maintain the packed product within this storage range.
RoHS status Compliant Request the applicable order document if the project requires compliance evidence.

Optical Specifications

Optical Item Specification Acceptance Note
Insertion loss ≤0.2 dB Define the test wavelength, reference cords, measurement direction, sampling level and report format when a batch acceptance record is required.
Interchangeability loss ≤0.2 dB Define the mating sequence, connector set and calculation method before using this value as a batch acceptance criterion.
Repeatability ≤0.2 dB Use the project test plan to define the number of matings and calculation method.
Durability change <0.2 dB after 1,000 insertions Define pre-test and post-test measurement conditions when qualification evidence is required.

Loss-budget note

The ≤0.2 dB value applies to adapter insertion loss. It must not be relabeled as connector return loss, single-connector loss or complete channel loss. State the return-loss requirement, operating wavelength and mated-connection test method separately when they are part of the project acceptance plan.

Mechanical and Configuration Table

Configuration Area Standard Configuration Ordering Requirement
Channel count Duplex Confirm two LC channels are required at each panel position.
Body arrangement High-low Do not substitute a high-high, standard duplex or simplex body without checking the panel drawing.
Mounting Without flange Provide panel material, opening and retention detail.
Sleeve Ceramic Include sleeve material in the approved BOM and incoming inspection record.
Durability >1,000 mating cycles State any required sampling, cycling and post-test loss method.
Dimensions / panel cutout Confirm by drawing or sample Supply the cutout dimensions, panel thickness and retention detail before batch production.

Cable and Connector Compatibility

Component or Node Compatible Configuration Project Field to Confirm
Connector interface LC, duplex Confirm the mating connector body, polarity and boot clearance.
Polish PC Keep the same project polish definition on both sides of the adapter.
Fiber category Multimode; OM4 product designation Confirm the patch cords, pigtails and permanent link are specified for the same multimode category.
Patch cords and pigtails LC multimode connectorized assemblies State OM4 fiber, cable construction, polarity, connector polish, length and jacket requirement.
Panel hardware Flange-free high-low duplex opening Provide the exact cutout, plate thickness, retention method and rear clearance.
Typical network locations Telecom, LAN, WAN, premise, video, FTTx, CATV and device interconnection points Identify the actual rack, panel, ODF, faceplate or equipment interface in the BOM.

Application scenarios

LC OM4 DX High-Low Adapter Applications and Cabling Solutions

This adapter is intended for serviceable LC duplex multimode connection points where the OM4 designation, high-low panel footprint and optical acceptance values must remain controlled.

LC OM4 Duplex High-Low Adapter for Data Center Patching

Ordering only by "LC duplex" can put a high-high or standard body into a panel designed for a high-low opening. This violet OM4 adapter combines two LC multimode PC channels, a ceramic alignment sleeve and ≤0.2 dB insertion loss at the passive cross-connect between equipment patch cords and the panel-side link. Use it in compatible data center patch panels or ODF trays with LC OM4 assemblies. Before procurement, confirm the panel cutout, polarity, patch-cord boot clearance, port-color schedule, test-record requirement and whether the selected panel retains a flange-free body.

Enterprise LAN and Campus Backbone Cross-Connects

Mixed OM3, OM4 and singlemode fields can produce wrong patching when adapter color and fiber category are not controlled in the BOM. The violet housing identifies this OM4-designated multimode version, while the duplex high-low geometry keeps the paired LC interface in one panel position. Install it at the building distributor, floor distributor, campus cross-connect or equipment-room faceplate between LC OM4 patch cords and pigtails. Confirm PC polish, port numbering, panel footprint, cable polarity, cleaning procedure and whether the −40°C to +85°C working range covers the specified equipment-room conditions.

OEM Patch Panel and ODF Assembly

Panel assemblers risk rework when they approve the connector type but omit the adapter body geometry and retention format. This product specifies LC duplex high-low construction, mounting without a flange, a violet housing and a ceramic sleeve, giving the OEM BOM separate fields for interface, footprint, color and alignment material. It is installed in the adapter plate of a rack panel, wall enclosure or ODF tray and mated to LC multimode pigtails and patch cords. Before batch production, approve the cutout drawing, plate thickness, retention detail, orientation, rear clearance, labels, packing arrangement and inspection sample.

Serviceable Multimode Device and Video Links

A direct patch-cord join or incorrectly selected singlemode adapter can complicate maintenance at a device interconnection point. The LC OM4 DX High-Low Adapter provides a removable duplex multimode PC interface with durability above 1,000 mating cycles, making it relevant where equipment or test leads are periodically replaced. Position it in a compatible premise panel, device faceplate, video-transmission rack, localized WAN room, CATV cabinet or FTTx indoor cross-connect. Confirm that both mating assemblies are LC multimode, then define polish, polarity, fiber category, panel opening, environmental conditions and the required optical acceptance method.

 

Project ordering

LC OM4 DX High-Low Adapter Ordering Configuration

Include these fields in the RFQ so the ordered adapter matches the optical interface and the physical panel opening.

Ordering Field Standard Configuration Information to State on the RFQ
Product identifier LC OM4 DX High-Low Adapter Product name, order quantity and approved image, drawing or sample reference.
Connector interface LC duplex Confirm mating connector body, duplex polarity and port orientation.
Fiber and polish Multimode / OM4 designation; PC polish Confirm the patch-cord and pigtail specifications on both sides.
Body style Duplex high-low State high-low orientation and provide the panel cutout drawing.
Mounting Without flange Panel material, thickness, retention detail and rear clearance.
Sleeve material Ceramic Include ceramic sleeve in the controlled BOM.
Housing color Violet Confirm the project color standard and approved shade sample if color matching is critical.
Optical requirement Insertion loss ≤0.2 dB; repeatability ≤0.2 dB Sampling plan, reference cords, wavelength, direction, uncertainty and report format.
Durability requirement >1,000 cycles; change after 1,000 insertions <0.2 dB State whether qualification evidence or lot testing is required.
Identification Project-defined Product label, logo artwork, lot code, carton marks and barcode data.
Packaging Project-defined Dust protection, unit quantity, bag or tray format, carton quantity and packing-list format.
Documents Project-defined Datasheet, drawing, inspection record, optical test report and applicable RoHS document.

Recommended RFQ line

LC OM4 DX High-Low Adapter, duplex LC multimode PC, violet housing, ceramic sleeve, without flange, insertion loss ≤0.2 dB, durability >1,000 mating cycles, for panel cutout drawing [reference], quantity [ ], optical test requirement [ ], labels [ ] and packaging [ ].

OEM and project support

OEM LC OM4 Adapter and Panel-BOM Control

For repeat panel orders, control the adapter and its mating components through one approved drawing, BOM and inspection plan.

Panel Fit Review

Match the duplex high-low, flange-free housing to the cutout, panel thickness, orientation and rear cable clearance.

Connector BOM Review

Align the LC interface, PC polish, OM4 multimode assemblies, polarity and violet port-color schedule.

Optical Test Definition

Translate the ≤0.2 dB requirement into a project sampling plan with defined test conditions and report format.

Sample Confirmation

Approve appearance, panel retention, mating fit and the required optical check before batch assembly.

Label and Packing Control

Provide logo artwork, product labels, lot identification, barcode data, unit packing and carton-mark instructions.

Repeat-Order Revision Control

Freeze the adapter body, color, sleeve, test criteria, labels and packing into one revision-controlled BOM.

 

Company background

Why Glory Optical for LC OM4 Adapter Project Supply

Glory Optical Communication is a Ningbo-based passive fiber optic infrastructure manufacturer founded in 2008, with a 20,000 m² facility, more than 300 passive optical products, supply to over 50 countries and OEM/ODM project support.

Connectorized Product Assembly

Glory's product scope includes fiber optic adapters, connectors, patch cords, pigtails and pre-terminated cable assemblies. This allows the LC OM4 adapter, mating cords and panel components to be reviewed as one connection path rather than unrelated line items.

Optical and End-Face Checks

Connectorized products can be checked for insertion loss, return loss and end-face condition where applicable. State the exact checks, sampling level and report format on the LC adapter order.

OEM / ODM Confirmation Workflow

Project support can include specification review, drawing or photo confirmation, sample planning, testing, labeling, packaging and batch supply. For this adapter, the controlled inputs are the high-low footprint, panel cutout, color, sleeve material and optical acceptance plan.

Project Documentation

Project buyers may request datasheets, drawings, applicable test reports, packing photos, product labels and compliance documents. The final document set depends on the confirmed adapter configuration and order acceptance requirements.

Build an orderable OM4 panel connection

Specify the LC OM4 DX High-Low Adapter Around the Actual Panel Drawing

Send the panel cutout, LC duplex polarity, OM4 patch-cord or pigtail specification, high-low orientation, quantity, optical acceptance method, labels and packaging requirements. Glory Optical can review the adapter and mating panel BOM before quotation.

Glory Support

From sample verification to project configuration

Confirm the physical interface and cable code before bulk production, then lock the approved configuration into drawings and order codes.

3-Year Service Policy

Defined return, replacement and repair support is available according to the applicable warranty terms and confirmed order documentation.

OEM/ODM Configuration

Port count, cable length, splitter structure, mounting accessories, labeling and packaging can be configured for the project.

Sample & Drawing Approval

Sample evaluation and approved drawings help confirm interface fit, sealing and cable compatibility before volume deployment

gloryoptic
Our Quality Promise

Comprehensive 3-Year Warranty

We confidently back all our products with a 3-year warranty. Our specific service policy is: within one year for quality issues, we take full responsibility for returns; within two years, for replacements; and within three years, for repairs.

Clear & Competitive MOQ

We welcome both trial and bulk orders. Our standard Minimum Order Quantity (MOQ) is 50 units. We also offer free samples for testing​ to help you evaluate our quality with confidence.

Fast & Reliable Logistics

We guarantee delivery within 10 days​ for standard items. Our logistics advantage includes cost-effective door-to-door service​ to simplify shipping for you.

Our Foundation

Backed by 18 years of experience​ since 2008, we control quality from our own factory, accept OEM/ODM​ requests, and maintain ready stock​ for wholesale. We focus on delivering the optimal balance of price and quality​ directly to end customers​ worldwide.

 

Your trust is our priority. Partner with us for dependable fiber optic solutions supported by clear promises.

Hot Tags: lc om4 dx high-low fiber optic adapter, China lc om4 dx high-low fiber optic adapter manufacturers, suppliers, factory, a fiber optic cable, fiber optic installation, fiber optic jumpers, lc to sc fiber cable, network optical cable, optical connectors

Send Inquiry