LC OM4 SX Adapter Without Flange

Send Inquiry
LC OM4 SX Adapter Without Flange
Details
Adapter Type: LC
Body Style: Simplex
Connector Polish Type: PC
Connector Fiber Mode: Multi mode
Insertion Loss: ≤0.2dB
Durability: >1000times
Mounting Type: Without Flange
Aligment Sleeve Material: Ceramic
Color: Violet
RoHS Compliancy Status: Compliant
Category
Fiber Optic Adapter
Share to
Description

Designed for Compact OM4 LC Patching

This adapter is used when a network cabinet, fiber panel, cassette or device faceplate needs a clean LC connection point without adding screw flanges around the port. It helps installers keep OM4 multimode links easy to identify, easy to patch and easier to inspect during maintenance.

No-Flange Installation

The compact housing supports panel layouts where the adapter is fixed by the panel opening and side latch structure instead of external screw ears.

Ceramic Sleeve Alignment

The internal ceramic sleeve keeps LC ferrules centered, helping reduce mating instability caused by poor connector alignment.

OM4 Port Recognition

The violet body makes OM4 multimode ports easier to distinguish from single-mode, OM3 or mixed patching zones inside a cabinet.

 

Product Images

These product views help confirm the LC simplex structure, no-flange body shape and OM4 color identification before panel design or bulk purchasing.

Technical Specifications

 

 

Product Name LC OM4 Simplex Fiber Optic Adapter Without Flange
Adapter Type LC
Body Style Simplex
Connector Polish Type PC
Fiber Mode Multimode, OM4
Insertion Loss ≤0.2 dB
Repeatability ≤0.2 dB
Durability More than 1000 mating cycles; optical change after repeated insertion is less than 0.2 dB
Mounting Type Without flange
Alignment Sleeve Material Ceramic
Housing Color Violet
Working Temperature -40°C to +85°C
Storage Temperature -40°C to +85°C
Compliance RoHS compliant

 

Installation Guidance for Panels and Equipment Ports

For OM4 links, adapter installation is not only a mechanical step. Port orientation, connector cleanliness, patch-cord routing and label consistency all affect how quickly technicians can deploy and troubleshoot the link later.

Confirm the panel cutout and fixing direction

Use this no-flange version only where the adapter opening and latch position match the panel or module design. Avoid forcing the adapter into an undersized cutout, because housing deformation may affect connector mating.

Keep the LC key orientation consistent

Install the adapter in the same orientation across the patch panel. A consistent latch direction reduces wrong-port patching and makes LC connector insertion easier during cabinet maintenance.

Clean before final patching

Keep dust caps on unused ports. Before connecting OM4 patch cords, inspect and clean connector end faces to avoid contamination-related loss or intermittent optical margin.

Route the patch cord without side pressure

Leave enough clearance in front of the adapter so the LC boot is not pressed by cabinet doors, cable managers or neighboring jumpers. The adapter should not become a load-bearing point for the patch cord.

Label OM4 ports by link function

Use port labels such as uplink, access switch, equipment port, test port or spare. Good labeling is especially useful when OM4 multimode and single-mode links share the same rack.

Installation note: for high-density projects, confirm adapter body style, panel thickness and latch direction with samples before mass panel production.

 

Application Layer: Where This Adapter Fits

This product is a passive LC coupling point. It does not define the transmission distance by itself, but it helps build a stable and organized OM4 multimode connection channel when matched with the correct patch cord, equipment port and optical module.

Application Layer Typical Position Why This Adapter Is Useful
Data communication racks LC patch panel, equipment cabinet, network distribution area Provides a compact LC interface for OM4 patching where port density and clean cable routing are important.
Enterprise LAN backbone Floor distributor, main equipment room, cross-connect cabinet Helps organize multimode fiber runs between switches, patch panels and backbone cabling sections.
Telecom and access equipment Optical distribution frame, subrack, test access point Creates a replaceable LC connection point for device-side or patch-cord-side maintenance.
Video and CATV optical systems Equipment interface, indoor distribution point, service cabinet Supports neat LC connector coupling when multimode patching is used inside controlled indoor environments.

 

Suitable for These Network Scenarios

The adapter can be selected for projects that need LC multimode coupling in compact spaces, especially when the designer wants color-coded OM4 identification and a simple no-flange mounting structure.

  • OM4 multimode patching in LAN and equipment rooms
  • Patch-cord-to-patch-cord connection inside optical panels
  • Connections between equipment ports and fiber jumpers
  • Telecommunication network cabinets and communication systems
  • Indoor FTTx, CATV, WAN and video transmission cabling points
  • OEM panel assembly where compact adapter footprint is required
LC adapter specification and application detail image

 

Pre-Installation Checklist

Panel FitConfirm cutout size, panel thickness and latch direction.
Fiber MatchUse with LC OM4 multimode patch cords and the correct equipment interface.
Port CleanlinessKeep caps in place and clean connectors before live service patching.
Cable RoutingLeave enough bend and boot clearance in front of the adapter.

 

Quality Control and Acceptance Points

A small LC adapter can create large troubleshooting costs if it is loose, contaminated or mismatched. Glory Optical recommends checking both mechanical fit and optical performance before using adapters in volume assembly.

Mechanical Inspection

Check housing appearance, latch strength, connector insertion feel and port consistency before packing or panel assembly.

Optical Performance

Verify low insertion loss and stable repeatability for the required project batch, especially for high-density patching systems.

Packaging Protection

Use dust caps and clean packaging so adapters arrive ready for installation without extra cleaning or sorting work.

 

Ordering Information

For quotation, please confirm the following information so the adapter can be matched to your panel design and cabling system.

  • Connector interface: LC simplex
  • Fiber mode and color: OM4 multimode, violet housing
  • Mounting style: without flange
  • Sleeve material: ceramic
  • Quantity, packaging method and any labeling requirement
  • Whether samples are needed for panel fit verification before bulk order

gloryoptic
Our Quality Promise

Comprehensive 3-Year Warranty

We confidently back all our products with a 3-year warranty. Our specific service policy is: within one year for quality issues, we take full responsibility for returns; within two years, for replacements; and within three years, for repairs.

Clear & Competitive MOQ

We welcome both trial and bulk orders. Our standard Minimum Order Quantity (MOQ) is 50 units. We also offer free samples for testing​ to help you evaluate our quality with confidence.

Fast & Reliable Logistics

We guarantee delivery within 10 days​ for standard items. Our logistics advantage includes cost-effective door-to-door service​ to simplify shipping for you.

Our Foundation

Backed by 18 years of experience​ since 2008, we control quality from our own factory, accept OEM/ODM​ requests, and maintain ready stock​ for wholesale. We focus on delivering the optimal balance of price and quality​ directly to end customers​ worldwide.

 

Your trust is our priority. Partner with us for dependable fiber optic solutions supported by clear promises.

Hot Tags: lc om4 sx adapter without flange, China lc om4 sx adapter without flange manufacturers, suppliers, factory, a fiber optic cable, fiber optic installation, fiber optic jumpers, lc to sc fiber cable, optical connectors, plc fiber

Send Inquiry