Optitap MST Box

Send Inquiry
Optitap MST Box
Details
Model: 6 port Optitap MST Box GL-MST01-06
• Multiport Service Terminals incorporate hardened connector technology designed to withstand rugged outside plant environments.
• Optitap® Hardened connectors are factory-terminated and environmentally sealed for use in optical drop cable deployments.
• Plug-and-play adapter ports ensure rapid cable ​​installation​​ in the outside plant access section of the network.
• IP68 protected.
Category
Fiber Optic Termination Box
Share to
Description

GL-MST01-06 6-Port OptiTap MST Box

The GL-MST01-06 is a six-port outdoor Multiport Service Terminal (MST) for connecting distribution fibers to subscriber drop cables. Its IP68 enclosure measures 112 × 267.5 × 89 mm and provides hardened connection interfaces, with a cable-gland or hardened-adapter feeder entrance. Custom feeder lengths and stub-tail configurations support planned FTTH distribution points; specify the matching connector assembly and mounting kit for pole, pedestal, handhole or strand installation.

GL-MST01-06 six-port outdoor Optitap MST box with hardened connector ports and feeder stub

Six Hardened Ports for Outdoor Fiber Access

External drop connections with selectable feeder entrance and stub-tail configuration. Confirm the matching drop assembly and port-to-fiber map for the order.

Model: GL-MST01-06

Protection: IP68 · Port count: 6

Published size: 112 × 267.5 × 89 mm

View technical specifications   |   Review ordering details

Product Line: Outdoor Pre-connectorized Multiport Service Terminals

Catalogue family: Fiber Terminals → Multiport Service Terminals. The GL-MST01-06 is the six-port model in the GL-MST01 series, providing hardened drop connections at an outdoor distribution-to-subscriber node.

Network role: In the illustrated FTTP arrangement, splitting takes place at the Fiber Distribution Hub (FDH), and the MST connects the distribution cable to subscriber drops. Specify any required internal splitter as part of the approved circuit and configuration.

Browse the Multiport Service Terminal family

GL-MST01-06 MST Box Features

Six External Drop Connection Ports

Six externally accessible ports provide the connection positions for matched drop assemblies. With the approved pre-terminated configuration, an additional drop can be connected without opening the terminal enclosure. Record the numbered port-to-fiber map and unused-port sealing arrangement during commissioning.

Hardened Interface Configurations

The range lists hardened SC, hardened LC duplex and hardened MPO adapter options. Select the actual interface for the ordered assembly and match its mechanical housing, optical interface and cable plug. Port count and fiber count depend on that selected configuration; the listed options are not a mixed-port bill of materials.

Selectable Feeder Entrance and Stub

A cable gland or hardened-adapter entrance supports different feeder connection plans. Feeder fiber counts of 1, 2, 4, 6 or 8 cores and customized lengths are listed. Approve the input termination, fiber assignment and stub routing with the complete assembly drawing.

IP68 Enclosure for Outdoor Nodes

The terminal has a stated IP68 protection rating and a published size of 112 × 267.5 × 89 mm. Select the sealing components for the feeder and drop configuration, then confirm the required assembled test conditions. Keep inspection and cleaning procedures with the installation instructions.

Mounting Options for the Access Route

Pole, pedestal, handhole and strand mounting are listed in the specifications; wall and pole installation are also described. Specify the kit for the actual support structure, connector access and cable routing. Confirm bracket dimensions, fixing arrangements and clearance with the approved installation drawing.

General Technical Specifications

Parameter

Specification / configuration

Item Name

Optitap MST Box GL-MST01-06

Size

112x267.5x89mm

IP Rate

IP68

Product Type

Access Terminal

Port

6 ports

Adapter

Hardened SC, Hardened LC Duplex, Hardened MPO

Entrance

Cable gland or Optitap Hardened adapter

Feeder Cable

1,2,4,6,8 cores for options

Feed Cable Length

Customized

Stub Type

Stub Tail

Temperature range (category to confirm)

-40 to +85℃

Mounting Method

Pole, pedestal, handhole, or strand mounting

Temperature specification: Confirm whether the listed −40 to +85°C range applies to operation, storage or another condition for the selected assembly. Confirm the connector option and installed port arrangement separately from the six-port enclosure designation.

Cable and Optical Specifications

Parameter

Specification / configuration

Cable Type

Flat drop cable

Cable Size

3.0x4.5mm; 4x7mm; 4.5x8.1mm; 4.5x9.8mm

Cable Quantity

1

Cable Stub Length

50meter to customized

Attenuation, maximum

0.30 dB/km @ 1550 nm | 0.40 dB/km @ 1310 nm

Directivity, minimum

60 dB

Wavelength Range

1260–1635 nm

Insertion Loss, Terminal Connector, max.

0.4dB

Return Loss, Connector, minimum

65dB

Optical acceptance: Cable attenuation is stated per kilometre; the 0.4 dB maximum insertion loss and 65 dB minimum return loss are listed as connector values. Confirm their applicable interface, measurement reference and test conditions. Confirm the component and test definition for directivity; this entry does not define a splitter ratio.

Cable ordering: Confirm the meaning of the "50meter to customized" stub-length entry, the selected flat cable size and the required input termination in the quotation and assembly drawing.

GL-MST01-06 Dimensional Drawing

GL-MST01-06 six-port Optitap MST box dimensional drawing with enclosure and mounting views

Published Size: 112 × 267.5 × 89 mm

Review the body, mounting base, feeder exit and connected drop plugs together when checking installation space.

Confirm the dimension order, required tolerances and bracket clearance against the approved model-specific drawing. The original product drawing is retained here for configuration review.

MST Position in an FTTP Distribution Network

FTTP network diagram showing a fiber distribution hub, pedestal handhole and aerial MST nodes, and subscriber drop cables

From Distribution Cable to Subscriber Drops

Feeder cable → FDH with optical splitting → distribution cable → MST → drop cables → subscriber premises.

The illustration shows pedestal, handhole and aerial MST locations. Select the mounting kit and connector arrangement for each installed node.

This drawing shows an FTTP subscriber network. Any FTTA design requires its own equipment interface and optical-path confirmation.

FTTH and FTTA Application Planning

FTTH Distribution-to-Drop Connections

At a neighborhood distribution point, adding subscriber drops can require repeated access to a sealed enclosure. The GL-MST01-06 provides six external hardened connection positions so matched pre-terminated drops can be connected at the port. In the illustrated FTTP architecture, place the terminal downstream of the FDH split and connect it to the planned distribution cable. Before ordering, confirm the feeder fiber count, port map, drop plug and optical budget. Identify any feeder splice work separately from subscriber drop connection, and approve the arrangement for unused ports and future service activation.

Pole, Pedestal, Handhole and Strand Routes

An access route may use several support structures, each with different space and cable-routing constraints. The listed mounting options let the same six-port model be specified for pole, pedestal, handhole or strand locations when the corresponding kit is approved. Position the MST at the distribution-to-drop node with access to each connected plug and the feeder exit. Confirm bracket geometry, fastening parts, cable support, bend limits and installation clearance. For handholes or exposed locations, define the required assembled IP68 test conditions and the inspection procedure for seals and mating surfaces before procurement.

FTTA Fiber Connections at Mobile Sites

Tower and rooftop links require connector assemblies matched to the radio equipment and the site fiber plan. The GL-MST01-06 description includes FTTA applications, while its adapter list includes hardened SC, LC duplex and MPO options. Position the selected configuration at the approved outdoor connection point between the distribution run and matched equipment leads. Before ordering, confirm the exact receiving interface, fiber mapping, duplex polarity or multifiber arrangement where applicable, feeder construction and mounting kit. Have the radio-link design define the optical path; an internal splitter is not established by the six-port enclosure specification.

Selection and Ordering Details

Confirm before ordering

Required project details

Model and interface

GL-MST01-06; exact hardened adapter and mating cable connector parts

Port and fiber mapping

Numbered six-port schedule, interface-specific fiber allocation and unused positions

Input connection

Cable gland or hardened-adapter entrance; feeder end and splice location

Feeder assembly

Selected core count, flat cable size, stub length and cable construction

Optical circuit

Approved distribution circuit; any required splitter and its ratio must be specified

Optical acceptance

Applicable connector loss limits, wavelengths, measurement reference and inspection records

Site conditions

Mounting kit, connected-plug clearance, temperature category and IP68 test conditions

Project supply

Quantity, sample drawing approval, port labels, packaging and requested documents

Configuration FAQ

Does six ports mean six fibers in every configuration?

The six-port designation identifies external connection positions. Fiber allocation depends on the selected SC, LC duplex or MPO interface and the approved internal map. Confirm the feeder count and port-to-fiber schedule for the ordered assembly.

Is a PLC splitter included as standard?

The illustrated FTTP network uses splitting at the FDH. No internal splitter ratio is specified for this GL-MST01-06 configuration. Include a circuit drawing and the required splitter specification if the project needs splitting inside the terminal.

What supports cable management during maintenance?

A documented feeder route, numbered port map and identified drop leads help technicians trace connections and replace the correct cable. Keep matched connector parts, inspection instructions and the approved layout with the installation record.

Related Product Family

Multiport Service Terminals   |   GL-MST01-06 reference product

About Glory Optical

Glory Optical manufacturing facility in Ningbo, China

Glory Optical facility, Ningbo

Glory Optical

Founded in 2008 · Ningbo, China · OEM/ODM support

Ningbo Glory Optical Communication Co., Ltd. manufactures passive fiber optic products and supplies telecom operators, ISPs, contractors, distributors and OEM/ODM buyers. Our portfolio covers fiber boxes, splice closures, PLC splitters, fiber optic cables, patch cords, pigtails, adapters, MTP/MPO assemblies and installation accessories for fiber network projects.

Manufacturing & OEM/ODM Support

Manufacturing capabilities across our product families include mold development, enclosure molding, component assembly and fiber cable assembly. OEM/ODM projects can cover drawings, product configuration, samples, branding, labels and packaging, according to the selected product and confirmed requirements.

Testing Capabilities

Glory Optical supports inspection and testing according to confirmed product specifications and order requirements. The following videos show examples from our testing activities.

Water Spray Testing

Watch on YouTube

Sealing Performance Testing

Watch on YouTube

Water Resistance Testing

Watch on YouTube

Specification Review & Project Documentation

Before batch production, confirm the drawing or sample, product configuration, inspection requirements and packing details. For connectorized products, applicable inspection can include insertion loss, return loss and connector end-face checks. Datasheets, drawings and applicable test documents can be discussed for the order.

About Glory Optical | OEM/ODM Services

Discuss Your Product or Project Requirement

Send the product model, quantity, application and required configuration for quotation or sample discussion. Include any drawing, labeling, packaging and documentation requirements so our team can review the order details.

Request a Quote | Email Sales

Email: sales@gloryoptic.com

Hot Tags: optitap mst box, China optitap mst box manufacturers, suppliers, factory

Send Inquiry