OS2 MPO-24 To 2×MPO-12 Breakout Cable

Send Inquiry
OS2 MPO-24 To 2×MPO-12 Breakout Cable
Details
Convert a 24-fiber OS2 distribution connection into two 12-fiber connection points with this Glory Optical breakout assembly. One female MPO-compatible 24-fiber end serves the common side, and two female 12-fiber ends serve the branches. All three interfaces use APC polish, with Type A wiring and a nominal 1 m cable length.
Category
MTP/ MPO
Share to
Description

OS2 MPO-24 to 2×MPO-12 Breakout Cable

Convert a 24-fiber OS2 distribution connection into two 12-fiber connection points with this Glory Optical breakout assembly. One female MPO-compatible 24-fiber end serves the common side, and two female 12-fiber ends serve the branches. All three interfaces use APC polish, with Type A wiring and a nominal 1 m cable length.

Reference photograph of multi-fiber connector housings and cable boots

Connector-style illustration. The specified assembly has one 24-fiber common end and two 12-fiber branches; pictured colors and connector variants are illustrative.

Keep a Base-24 Connection Available to Two Base-12 Paths

24 total fibers · OS2 single mode · female APC terminations · Type A · 1 m · OFNP

Use the assembly at a managed connection point where the planned system changes from a 24-fiber interface to two 12-fiber groups. Each branch provides its own multi-fiber termination, so the distribution drawing can identify and service the two groups separately.

View the connectivity range / Explore MPO cabling

Review This Conversion Build   See the Full Specification

A Passive 24-Fiber to Two-Group Conversion

Common interface First branch Second branch
One 24-fiber female APC connector One 12-fiber female APC connector One 12-fiber female APC connector
24 populated optical paths 12 assigned optical paths 12 assigned optical paths
Type A configuration record Branch identity to be confirmed on the drawing Branch identity to be confirmed on the drawing

The two branch groups account for the full 24-fiber population. This is passive fiber routing: the assembly does not divide optical power or perform a data-rate conversion. Confirm the precise position assignment and branch identifiers before releasing the cable schedule.

Technical Specification of the 1 m OS2 Assembly

Parameter Configuration and rating
Product name OS2 MPO-24 to 2×MPO-12 Breakout Cable
Nominal cable length 1 m (3 ft nominal)
Connection format 1 × 24-fiber MPO-compatible end to 2 × 12-fiber MPO-compatible ends
Total fiber population 24 fibers; two 12-fiber branch groups
Single-mode fiber OS2 9/125 μm
Common connector US Conec MTP®-24 Elite female (non-pinned)
Branch connectors 2 × US Conec MTP®-12 Elite female (non-pinned)
Connector polish APC at all three ends
Polarity designation Type A
Jacket classification Plenum (OFNP)
Glass fiber specification G.657.A1
Operating wavelengths 1310 / 1550 nm
Cable outside diameter 3.0 mm
Specified breakout length 0.5 m
Minimum optical-fiber bend radius 10 mm
Minimum finished-cable bend radius 10D dynamic / 5D static; D = outside diameter
Installation tensile load 66 N
Long-term / short-term tensile strength 80 N / 240 N
Connector insertion loss ≤0.35 dB maximum; 0.15 dB typical
Connector return loss ≥60 dB
Fiber attenuation at 1310 nm ≤0.35 dB/km
Fiber attenuation at 1550 nm ≤0.21 dB/km
Operating temperature −10 to +60°C (14 to 140°F)
Storage temperature −10 to +70°C (14 to 158°F)

Length values need a common measurement reference on the approved drawing. The nominal cable length is 1 m and the specified breakout length is 0.5 m; do not add the two values to create an assumed overall length.

Ferrule Alignment, Spring Support and Cable Retention

Generic exploded connector illustration showing ferrule, housing, gender hardware, spring components and boot

Generic connector anatomy. Alternative gender hardware is shown together; the ordered common and branch ends are all female.

Understand the Termination Before Planning Service Access

The multi-fiber ferrule presents the optical positions at the mating face. The housing and its key establish the insertion orientation, while the internal spring mechanism supports the ferrule assembly.

Different connector genders use different guide-pin hardware. For this configuration, the three terminations are pinless and receive the alignment pins from their mating interfaces. The drawing illustrates component principles rather than a 24-position or 12-position wiring map.

At the rear of each connector, the retention parts and boot support the cable exit. Provide room to operate the latch and withdraw the connector without pulling against the other branch.

Hardware area Installation consideration
Ferrule and optical face Inspect the correct APC face and the specified position population for each end.
Gender hardware Use complementary pinned mating interfaces for all three female terminations.
Housing key and latch Record adapter orientation and leave access to the release mechanism.
Boot and rear retention Support the cable transition without a sharp turn at the connector body.

Coordinate Three Female APC Interfaces

Diagram of complementary connector guide pins, guide holes, housing key and adapter alignment

Alignment concept showing pinned and pinless mating parts. APC polish and the fiber population are specified in the assembly data.

List the Common Port and Both Branch Ports Separately

The common connection requires an appropriate pinned 24-fiber APC counterpart. Each branch requires an appropriate pinned 12-fiber APC counterpart. Check the actual port hardware before selecting the adapters or cassette interfaces.

Specify APC mating geometry consistently at every connection. Housing fit, connector gender and optical polish are separate selection checks; a port schedule should record all three alongside the fiber count.

Type A identifies the assembly's wiring configuration. Trace the end-to-end position order through the complete channel, including any distribution modules, using the confirmed mapping rather than a generic gender diagram.

Bring the Two Branch Groups into the Cabling Plan

Concept illustration of a multi-fiber trunk connected to distribution modules

Modular-distribution concept. Modules and downstream connectors shown are examples and are selected separately from this conversion cable.

Adapt the Distribution Interface at the Patching Point

A 24-fiber route can be presented as two 12-fiber groups at the selected distribution point. Coordinate each group with the appropriate cassette, patch panel or other compatible passive interface, keeping the position map with the port identifiers.

The MPO patch-panel range provides a starting point for the mounting and cable-management discussion. Specify the loaded connector interfaces and module wiring when reviewing the optical configuration.

Each 12-fiber group can be assigned within an appropriately designed distribution system. The downstream connector format and duplex pairing, where required, are determined by the chosen modules and equipment-side leads.

Concept illustration of a multi-fiber cable joining patch-cord interfaces through complementary alignment hardware

Channel connection concept. The drawing illustrates a passive path; it does not define this cable's branch geometry or equipment compatibility.

Check the Full Optical Path Before Assigning a Link Rate

Select single-mode equipment and compatible interfaces for the planned channel. Optical wavelength, active-fiber requirements and the accumulated loss budget determine whether a particular equipment connection is suitable.

The 1 m assembly is a short conversion segment within that channel. It does not establish the system reach or make a port support a different breakout mode. Confirm equipment requirements separately from the passive connector conversion.

For multi-rack planning and port documentation, share the route and interface list with our data center cabling team.

Route a Short Assembly Without Loading the Connectors

For the 3.0 mm cable, the stated 10D moving and 5D stationary bend allowances correspond to 30 mm during movement and 15 mm after installation. The 10 mm optical-fiber value is a separate glass-fiber rating. Apply the finished-cable allowance to the jacketed route and leave both branch exits clear of sharp edges.

Plan the branch transition around the specified 0.5 m breakout length. Leave enough room to identify, unplug and service one 12-fiber end while the other remains in its managed position. Confirm measurement points on the drawing when the available space is tight.

The installation tensile rating is 66 N. Keep this handling limit distinct from the 80 N long-term and 240 N short-term tensile-strength values. Arrange support so pulling force and connector side loads do not concentrate at the branch transition or latch.

Verify All 24 Paths and Retain the Measurement Record

Begin with Clean APC Faces and the Correct Reference Leads

Inspect the common ferrule and both branch ferrules before mating. Clean each optical face with tools suitable for its connector format, then reinspect as required. Include the opposite mating faces in the same inspection process.

Test the Wiring and Loss as Separate Acceptance Tasks

Trace every populated position from the 24-fiber end to its assigned 12-fiber branch. Record continuity and the agreed Type A mapping against the branch labels. This position test confirms the passive routing independently of any equipment configuration.

Measure optical performance with a suitable single-mode reference method at the agreed wavelengths. The connector maximum insertion loss is 0.35 dB; 0.15 dB is a typical figure. Minimum return loss is 60 dB. Define the reporting scope clearly and include the rest of the channel when checking the complete system budget.

Product family What to specify
MTP/MPO cabling options Common and branch fiber counts, APC interfaces and the complete conversion map.
Distribution panels Panel loading, connector gender, cassette configuration and service clearance.
MPO-to-LC harness family A separate downstream harness option. Review its OS2 configuration and pairing if the project later requires duplex interfaces.

Release the Order Against a Confirmed Drawing

Order field Information to confirm
Base configuration OS2 9/125 μm, G.657.A1, 24 fibers, Type A, OFNP, nominal 1 m.
Three connector ends One female MTP®-24 APC and two female MTP®-12 APC connectors.
Mechanical layout 3.0 mm cable OD, 0.5 m breakout length, overall measurement references and branch identifiers.
Connection schedule Pinned counterpart at each interface, adapter orientation and full position mapping.
Acceptance documents Single-mode test reference, wavelengths, continuity record and agreed IL/RL report.
Supply details Quantity, labeling, packing instructions and required delivery date.

Provide the common port, the two destination ports and any existing distribution drawing when contacting Glory Optical. Our team can review the assembly definition, sample requirements and documentation with the purchasing and installation teams.

Request an OS2 Conversion Cable Quote   Browse Data Center Connectivity

MTP® is a registered trademark of US Conec Ltd. Connector and channel illustrations explain general construction and connection concepts; the approved drawing defines the supplied cable.

Glory Optical Product and Manufacturing Support

Glory Optical manufacturing facility in Ningbo, China

Glory Optical manufacturing facility in Ningbo, China

Passive Fiber Connectivity from Ningbo

Established in 2008 · Passive fiber components · OEM/ODM project supply

Glory Optical works with network operators, contractors, distributors and equipment brands on passive optical connectivity. Based in Ningbo, China, the company supplies cable assemblies and connection accessories alongside fiber enclosures, splice closures, splitters, adapters and pigtails for network installation and maintenance.

Turn the Interface List into an Approved Build

We review the required optical interfaces and mechanical layout around a drawing or sample. The production definition can cover connector configuration, fiber routing, identification and packing. Manufacturing activities across the range include cable assembly, component integration, enclosure molding and tooling development, depending on the product selected.

Examples from Our Wider Test Work

The following videos demonstrate enclosure and closure evaluations within the wider product range. For this conversion assembly, agree cable-specific checks such as ferrule inspection, position continuity, polarity and optical measurements as part of the order.

Enclosure Water-Spray Evaluation

Open the Demonstration

Closure Seal Evaluation

Open the Demonstration

Enclosure Water-Resistance Evaluation

Open the Demonstration

Define the Records Required at Delivery

Make the approved cable drawing the shared reference for purchasing, production and receiving. Agree any required configuration sheet, label schedule and applicable inspection results before supply. Identify the optical measurement setup and acceptance scope so the delivered records can be checked against the same build.

Glory Optical Product and Manufacturing Support | OEM/ODM Supply Support

Discuss Your Conversion Cable Schedule

Tell us the required quantities, common-side interface and two branch destinations. Include the available routing space and documentation needs. We can then discuss the configuration, sample review, packaging and delivery arrangements for the project.

Discuss a Quotation | Write to Our Sales Team

Email: sales@gloryoptic.com