OM4 MTP-12 UPC Female-to-Female Jumper

Send Inquiry
OM4 MTP-12 UPC Female-to-Female Jumper
Details
Glory Optical's OM4 MPO to MPO Patch Cord provides a 12-fiber multimode connection for cabinet patching and modular data center cabling. This 1 m assembly uses OM4 50/125 μm bend-insensitive fiber, female UPC interfaces at both ends, Type B crossed polarity and an OFNP jacket. Its 3.0 mm cable supports organized routing between matched panels, cassettes and equipment interfaces.
Category
MTP/ MPO
Share to
Description

OM4 MPO to MPO Patch Cord

Glory Optical's OM4 MPO to MPO Patch Cord provides a 12-fiber multimode connection for cabinet patching and modular data center cabling. This 1 m assembly uses OM4 50/125 μm bend-insensitive fiber, female UPC interfaces at both ends, Type B crossed polarity and an OFNP jacket. Its 3.0 mm cable supports organized routing between matched panels, cassettes and equipment interfaces.

product-800-800

OM4 12-fiber patch cord with protective caps. The specified assembly uses female UPC ends and Type B polarity.

12-Fiber OM4 Connection with Type B Polarity

Product line: Data Center Cabling / MTP®/MPO Assemblies

1 m · 12 fibers · OM4 · Female–female · UPC–UPC · Type B · OFNP

Low-loss terminations and bend-insensitive fiber support dense multimode patching. Match the female connectors to compatible pinned interfaces and verify the complete channel fiber map.

Request This Configuration

Technical Specifications

Parameter Specification
Product name OM4 MPO to MPO Patch Cord
Cable length 1 m (3 ft nominal)
Connector A US Conec MTP®-12 Elite female (non-pinned)
Connector B US Conec MTP®-12 Elite female (non-pinned)
Fiber mode / core and cladding OM4 multimode, 50/125 μm
Fiber count 12 fibers
Polish UPC to UPC
Polarity Type B, crossed
Cable jacket Plenum (OFNP)
Glass fiber Bend-insensitive fiber
Cable outside diameter 3.0 mm
Wavelengths 850 / 1300 nm
Insertion loss ≤0.35 dB maximum; 0.15 dB typical
Return loss ≥27 dB
Fiber attenuation at 850 nm ≤2.3 dB/km
Fiber attenuation at 1300 nm ≤0.6 dB/km
Minimum bend radius - optical fiber 7.5 mm
Minimum bend radius - finished cable 20D dynamic / 10D static; D = cable outside diameter
Connector durability 500 mating cycles
Tensile strength 80 N long term / 240 N short term
Operating temperature −10 to +60°C (14 to 140°F)
Storage temperature −10 to +70°C (14 to 158°F)

For the 3.0 mm cable, the 20D / 10D bend limits correspond to 60 mm during movement and 30 mm after installation. The 7.5 mm value applies to the optical fiber; use the finished-cable limits when routing the jacketed patch cord.

MTP® Connector Structure and Component Functions

US Conec generic MTP exploded view identifying dust cap, housing, ferrule, female pin spacer, male pin clamp, spring, spring push, crimp band and cable boot

Generic MTP® hardware architecture (US Conec). Male and female variants are illustrated; this OM4 assembly uses female UPC connectors.

From Fiber Alignment to Cable Strain Relief

The multi-fiber ferrule presents the 12-fiber array at the mating face. The keyed housing locates the connector in the adapter, while the spring and spring push support the ferrule assembly.

The female pin spacer and male pin clamp shown belong to different gender configurations. Both ends of this patch cord are female, with guide holes and no projecting alignment pins.

The rear crimp components retain the cable assembly, and the boot supports the cable transition. Keep protective caps fitted until inspection and connection.

Component group Function in the assembly
Ferrule and fiber array Present the 12 fibers at the connector mating face.
Keyed housing Provide orientation and retention at the matching adapter.
Spring and spring push Support the spring-loaded ferrule mechanism.
Female pin spacer / male pin clamp Alternative hardware for pinless and pinned connectors; this patch cord uses the female configuration.
Crimp band and cable boot Retain the cable and support the connector-to-cable transition.
Dust cap Protect the unmated interface during handling and storage.

Female Interfaces and Type B Polarity

FOA MPO connector mating diagram showing male guide pins, female guide holes, key, adapter and fiber row

Connector mating illustration (FOA): guide pins on one side align with guide holes on the other.

Check the Pinned Interface and Crossed Fiber Map

Both cable ends are female and must meet compatible pinned UPC interfaces. The adapter holds and orients the housings, while the guide pins and holes align the ferrules.

Type B reverses the 12-position fiber order from end to end: position 1 connects to position 12, position 2 to position 11, and so on. Its cable keying convention is key-up to key-up.

Confirm the adapter orientation, cassette wiring and optical-module Tx/Rx map as one channel. Connector gender, polish and the required active-fiber positions must all match the equipment.

Fiber positions at End A Matching positions at End B
1 · 2 · 3 · 4 12 · 11 · 10 · 9
5 · 6 · 7 · 8 8 · 7 · 6 · 5
9 · 10 · 11 · 12 4 · 3 · 2 · 1

Data Center Applications

FOA diagram of a multi-fiber cable linking two fanout modules, with pinned interfaces at the modules

Module-to-module connection illustration (FOA). Modules and duplex leads are selected separately.

Modular OM4 Cassette and Panel Connections

Use the patch cord between matched OM4 interfaces in a modular cabling system with suitable MPO patch panels. Specify the cassette fiber grade, adapter gender and internal fiber map together.

A suitable 12-fiber fanout module can route six duplex optical paths. The complete cassette and patch-cord combination must produce the required end-to-end polarity; modules and equipment-side leads are selected separately.

NHLink reference photograph of multiple MPO MTP patching rows and cable management at a rack

MPO/MTP rack application (NHLink). Shown cable colors and configurations vary from the specified OM4 patch cord.

Multimode Rack Patching and SR4 Channels

The 1 m assembly suits short patching routes within a cabinet. Route the cable through the selected managers and keep service loops within the finished-cable bend limits.

Compatible 40G QSFP+ SR4 and 100G QSFP28 SR4 equipment uses the active fibers of a 12-position multimode interface. Confirm the module pinout, UPC receptacle, connector gender and Type B channel map; the selected optics and loss budget determine reach.

For equipment interfaces, rack routing and channel configuration support, see our data center fiber cabling solution.

Installation and Optical Acceptance

Inspect, Clean and Verify the Fiber Map

Inspect both mating end faces and clean them as required before connection. Verify all 12 paths and the Type B position map, then measure optical performance with suitable multimode test equipment and reference leads.

Record insertion loss and return loss against the agreed test method and acceptance limits. The 0.15 dB insertion-loss figure is typical; the specified maximum is 0.35 dB and minimum return loss is 27 dB. Include all mated connections, fiber length and passive components in the complete channel budget.

Route the Cable Within Its Mechanical Limits

Support the cable transition behind the connector, avoid connector side loading, and keep routing and service loops within the finished-cable bend limits. Select the jacket for the installation space and project requirements.

Product or Solution Selection Guidance
MPO Patch Panels Plan OM4 cassette loading, UPC interfaces, adapter gender and the complete fiber map.
MTP®/MPO to LC Breakout Cables Explore LC fanout assemblies. The linked example uses OM3 fiber; specify OM4 fiber and the required polarity for an OM4 channel.
Data Center Fiber Cabling Solution Define the equipment interfaces, cable route and complete channel loss budget.

Ordering Configuration

Order item Configuration / information to supply
Assembly 1 m, 12-fiber OM4 50/125 μm, 3.0 mm cable, OFNP jacket
End A and End B Female UPC at both ends; confirm the matching pinned equipment or cassette interfaces.
Polarity Type B crossed; include the complete channel and cassette fiber map.
Optical acceptance Maximum IL ≤0.35 dB; typical IL 0.15 dB; RL ≥27 dB; agree the test method and records.
Channel and equipment Equipment model, interface polish, active-fiber positions, planned reach and complete loss budget.
Project supply Quantity, cable labels, packaging and required inspection documents.
Alternative assembly List any different length, polarity, gender or jacket separately for configuration review.

Send your cable schedule and interface requirements to Glory Optical for configuration review and quotation. Include a drawing or cassette port map where the jumper forms part of a structured channel. Contact our technical sales team for configuration questions.

Request a Quote   Browse Data Center Cabling

MTP® is a registered trademark of US Conec Ltd. Reference diagrams illustrate component and application principles; the supplied assembly follows the confirmed order configuration.

About Glory Optical

Glory Optical manufacturing facility in Ningbo, China

Glory Optical facility, Ningbo

Glory Optical

Founded in 2008 · Ningbo, China · OEM/ODM support

Ningbo Glory Optical Communication Co., Ltd. manufactures passive fiber optic products and supplies telecom operators, ISPs, contractors, distributors and OEM/ODM buyers. Our portfolio covers fiber boxes, splice closures, PLC splitters, fiber optic cables, patch cords, pigtails, adapters, MTP/MPO assemblies and installation accessories for fiber network projects.

Manufacturing & OEM/ODM Support

Manufacturing capabilities across our product families include mold development, enclosure molding, component assembly and fiber cable assembly. OEM/ODM projects can cover drawings, product configuration, samples, branding, labels and packaging, according to the selected product and confirmed requirements.

Testing Capabilities

The following videos show enclosure testing from the wider Glory Optical product portfolio. For this cable, confirm end-face inspection, continuity, polarity, insertion loss and return loss requirements with the order.

Water Spray Testing

Watch on YouTube

Sealing Performance Testing

Watch on YouTube

Water Resistance Testing

Watch on YouTube

Specification Review & Project Documentation

Before batch production, confirm the drawing or sample, product configuration, inspection requirements and packing details. For connectorized products, applicable inspection can include insertion loss, return loss and connector end-face checks. Datasheets, drawings and applicable test documents can be discussed for the order.

About Glory Optical | OEM/ODM Services

Discuss Your Product or Project Requirement

Send the product model, quantity, application and required configuration for quotation or sample discussion. Include any drawing, labeling, packaging and documentation requirements so our team can review the order details.

Request a Quote | Email Sales