MultiPort Flex Splitter Terminal with Supertap Connectors
Outdoor pre-connectorized fiber access terminal for FTTH / ODN networks
The MultiPort Flex Splitter Terminal with Supertap connectors combines optical splitting and factory-terminated drop connections for outdoor FTTH access networks. The published range lists 1×2, 1×4, 1×8, 1×12 and 1×16 PLC options, plus 1×2 coupler configurations, with an IP68 rating. Flexible connector leads suit compact boxes and telecommunications handholes; select the splitter circuit, matching SC/APC hardened interface and lead lengths for the planned distribution point.
Product Line: Pre-connectorized Fiber Access Terminals
Catalogue family: Fiber Terminals → MultiPort Flex Terminal. This product combines a flexible outdoor connector assembly with an integrated splitter or coupler. Select the PLC version for equal-split FTTH distribution; select the specified 1×2 coupler circuit when the optical design calls for a different power ratio.
View optical specifications | Review ordering details
MultiPort Flex Splitter Terminal Features
PLC Split Ratios for Subscriber Distribution
The published PLC range covers 1×2, 1×4, 1×8, 1×12 and 1×16 configurations. Select the output count against the planned subscriber group and the available optical budget. The two original structure drawings below illustrate the 1×2 and 1×4 versions.
Defined 1×2 Coupler Configurations
The optical table separately lists 10/90, 20/80, 30/70, 40/60 and 50/50 couplers. These ratios determine the allocation of optical power between two branches. Confirm the circuit and labelled ports before using an unequal coupler in a local-drop or downstream distribution design.
Factory-terminated SC/APC Connections
Factory-terminated, polished connectors provide the connection points for matched drop assemblies. SC/APC identifies the optical interface and polish; the Supertap housing has its own mechanical mating requirements. Confirm the connector part, keying, locking and sealing arrangement against the installed network.
Flexible Leads and Custom Stub Lengths
The compact body and flexible connector leads support routing within small boxes and telecommunications handholes. A custom-length, splice-on stub can be specified. Confirm whether the feeder end must remain splice-ready or be supplied with a connector, and approve the complete lead-length drawing.
IP68 Environmental Protection
The terminal has a stated IP68 environmental protection rating. Confirm the required assembled condition, mating parts, unused-port sealing and applicable test conditions for the installation. Include these details with the approved configuration and inspection requirements.
Structure Diagrams: 1×2 and 1×4 PLC Versions
|
|
1×2 PLC Splitter AssemblyStap (SC/APC) / Supertap 1×2 PLC assembly. Refer to the ordered configuration for input, output and lead-length details. |
|
|
1×4 PLC Splitter AssemblyStap (SC/APC) / Supertap 1×4 PLC assembly. Confirm the drawing for the selected split ratio, lead lengths and connector arrangement. |
General Specifications
|
Parameter |
Specification / configuration |
|---|---|
|
Product family |
MultiPort Flex Splitter Terminal / pre-connectorized fiber access terminal |
|
Network function |
Optical splitting or coupling at an outdoor fiber distribution point |
|
Application environment |
Outdoor FTTH access networks; compact boxes and telecommunications handholes |
|
Connector description |
Supertap connector; Stap (SC/APC) assembly |
|
PLC splitter configurations |
1×2, 1×4, 1×8, 1×12 and 1×16 |
|
1×2 coupler ratios |
10/90, 20/80, 30/70, 40/60 and 50/50 |
|
Environmental protection |
IP68; confirm the required assembled test conditions |
|
Feeder / stub options |
Custom-length splice-on stub; confirm end termination and lead lengths |
|
Connector preparation |
Factory-terminated polished connectors |
Optical Specifications and Splitter Configuration
Select the optical circuit before selecting the finished assembly. Review the loss limits for the selected ratio below, and confirm the test wavelengths, reference planes and whether connector losses are included in the quoted limits.
1×2 Coupler Configurations
|
Type |
Insertion loss (dB) |
Return loss (dB) |
|---|---|---|
|
10/90 1x2 Coupler |
≤11.5/1.05 |
≥55 |
|
20/80 1x2 Coupler |
≤8.2/1.6 |
≥55 |
|
30/70 1x2 Coupler |
≤6.3/2.2 |
≥55 |
|
40/60 1x2 Coupler |
≤4.5/3.0 |
≥55 |
|
50/50 1x2 Coupler |
≤3.9/3.9 |
≥55 |
Paired loss figures are listed in ratio order. Identify the corresponding output ports in the approved drawing. The 10/90 through 40/60 rows use unequal power ratios; 50/50 is an equal coupler configuration.
PLC Splitter Configurations
|
Type |
Insertion loss (dB) |
Return loss (dB) |
|---|---|---|
|
1x2 PLC Splitter |
≤4.2 |
≥55 |
|
1x4 PLC Splitter |
≤7.8 |
≥55 |
|
1x8 PLC Splitter |
≤10.9 |
≥55 |
|
1x12 PLC Splitter |
≤12.9 |
≥55 |
|
1x16 PLC Splitter |
≤13.9 |
≥55 |
Select one PLC ratio and confirm its numbered output schedule. The 1×12 and 1×16 options require their corresponding assembly drawings. Confirm the finished-assembly loss and the requested inspection records for the order.
FTTH Applications and Deployment Planning
FTTH Subscriber Drop Distribution
An outdoor distribution point needs a defined split plan as subscribers are added. This terminal combines a selected PLC circuit with factory-terminated connection leads, providing the interface between the distribution fiber and matched subscriber drop assemblies. Position it in the planned access box or telecommunications handhole, with enough room to route each lead and reach the mating connector. Before ordering, confirm the split ratio, active and reserved outputs, feeder termination, drop connector model and total path loss. Count the splitter loss together with the remaining cable and connection allowances in the project budget.
Compact Boxes and Telecommunications Handholes
Congested handholes leave limited space for a splitter body, connectors and cable routing. The low-profile terminal and flexible leads allow individual connections to be positioned around the available space. Use the selected assembly at the outdoor fiber distribution node, connected to its approved feeder and drop cables. Check the complete drawing with mating plugs attached, since body size alone does not determine the space needed. Confirm lead lengths, cable bend limits, fastening arrangements and the required IP68 test conditions before fixing the installation layout. No minimum bend radius is specified in the supplied product data.
Staged Expansion at Existing Access Points
Adding outputs to an existing access point can introduce an extra split and additional connector joints. The PLC variants provide a choice of output counts, while the separately listed couplers support different power ratios when the network design requires them. Place the chosen assembly at the approved outdoor distribution node and match both the incoming interface and the existing customer drops. Before procurement, confirm the receiving parts, any conversion assembly, numbered output map and remaining optical budget. The complete circuit and interface drawing should identify any splice work still required at the feeder end.
Mobile-site use: For a proposed distribution-box-to-RRH or cell-tower link, confirm the required point-to-point or passive optical topology and equipment interfaces before specifying a splitter assembly.
Selection and Ordering Details
|
Confirm before ordering |
Required project details |
|---|---|
|
Optical circuit |
PLC equal split or 1×2 coupler; selected ratio and numbered output map |
|
Input and output interfaces |
Exact mating connector parts, SC/APC polish, housing keying, locking and sealing |
|
Feeder and lead arrangement |
Splice-on or connectorized feeder end, cable construction, stub and branch lengths |
|
Optical acceptance |
Test wavelengths, measurement reference planes, connector inclusion and each output-path limit |
|
Installation fit |
Complete assembly drawing, attached-plug clearance, cable bend limits and securing method |
|
Environmental acceptance |
Required IP68 test conditions and assembled sealing arrangement |
|
Project supply |
Quantity, sample drawing approval, labels, packaging and requested inspection records |
Send Glory Optical the split plan, feeder and drop part numbers, lead lengths and installation drawing for configuration review. Request the selected assembly code, body dimensions, fiber grade, wavelength range and temperature limits with the quotation.
Related Terminal and Network Resources
MultiPort Flex Terminal product family | PLC splitters | Splitter terminal expansion and interface selection
About Glory Optical
|
Glory Optical facility, Ningbo |
Glory OpticalFounded in 2008 · Ningbo, China · OEM/ODM support Ningbo Glory Optical Communication Co., Ltd. manufactures passive fiber optic products and supplies telecom operators, ISPs, contractors, distributors and OEM/ODM buyers. Our portfolio covers fiber boxes, splice closures, PLC splitters, fiber optic cables, patch cords, pigtails, adapters, MTP/MPO assemblies and installation accessories for fiber network projects. Manufacturing & OEM/ODM SupportManufacturing capabilities across our product families include mold development, enclosure molding, component assembly and fiber cable assembly. OEM/ODM projects can cover drawings, product configuration, samples, branding, labels and packaging, according to the selected product and confirmed requirements. |
Testing Capabilities
Glory Optical supports inspection and testing according to confirmed product specifications and order requirements. The following videos show examples from our testing activities.
Water Spray Testing |
Sealing Performance Testing |
Water Resistance Testing |
Specification Review & Project Documentation
Before batch production, confirm the drawing or sample, product configuration, inspection requirements and packing details. For connectorized products, applicable inspection can include insertion loss, return loss and connector end-face checks. Datasheets, drawings and applicable test documents can be discussed for the order.
Discuss Your Product or Project Requirement
Send the product model, quantity, application and required configuration for quotation or sample discussion. Include any drawing, labeling, packaging and documentation requirements so our team can review the order details.
Email: sales@gloryoptic.com
Hot Tags: multiport flex terminals, China multiport flex terminals manufacturers, suppliers, factory