LC APC DX Flip Adapter

Send Inquiry
LC APC DX Flip Adapter
Details
Model: LC APC DX Flip Adapter
Adapter Type: LC
Body Style: Duplex
Connector Polish Type: APC
Connector Fiber Mode: Singlemode
Insertion Loss: ≤0.2dB
Durability: >1000times
Mounting Type: Without Flange
Aligment Sleeve Material: Ceramic
Color: Green
RoHS Compliancy Status: Compliant
Category
Fiber Optic Adapter
Share to
Description

Quick Identification

Product Name LC APC DX Flip Adapter
Product Category Fiber Optic Adapters
Connector Interface LC to LC duplex connection
Fiber Mode Singlemode
Color Code Green, commonly used for APC connector identification
Typical Use Duplex LC/APC patching in FTTH PON panels, optical distribution frames, indoor fiber boxes, telecom cabinets and high-density passive connectivity modules
Buyer Checkpoint Confirm panel cutout, flange requirement, dust-cap style and LC/APC patch cord direction before mass production.

Product Overview

The LC APC DX Flip Adapter is designed to join two LC/APC connectors in a duplex singlemode link. Its compact LC format helps increase port density compared with larger connector families, while the APC polish direction is suitable for optical paths where reflected power needs to be controlled.

Because this model is listed as without flange, it is best considered during panel design rather than after the patch panel has already been tooled. The retention structure, panel thickness and cutout tolerance should be checked together so the adapter locks firmly without creating stress on the connector body.

The ceramic alignment sleeve is the key precision component inside the adapter. It guides the two connector ferrules into position, helping the link maintain stable optical performance during installation, cross-connection and later service access.

LC APC DX Flip Adapter

Technical Data

Model LC APC DX Flip Adapter
Adapter Type LC
Body Style Duplex
Connector Polish Type APC
Connector Fiber Mode Singlemode
Insertion Loss ≤0.2 dB
Durability >1000 times
Mounting Type Without flange
Alignment Sleeve Material Ceramic
Color Green
RoHS Compliancy Status Compliant

General LC Adapter Performance Reference

Parameter Reference Value Why It Matters
Insertion Loss ≤0.2 dB Helps protect link margin in PON, access and cabinet cross-connect links.
Alternating / Interchange Loss ≤0.2 dB Useful when adapters are matched with connectors from different production batches.
Repeatability ≤0.2 dB Supports repeated patching and maintenance without obvious performance drift.
Durability Change Less than 0.2 dB after 1000 insertion cycles Important for distribution panels and test positions that may be accessed many times.
Working Temperature -40°C to +85°C Suitable for telecom rooms, equipment shelters and protected outdoor cabinets.
Storage Temperature -40°C to +85°C Supports warehouse storage and transportation in different climate zones.

Why This Adapter Is Different from a Standard Simplex Adapter

Duplex LC Port in One Position

One adapter body supports a paired LC connection, which is useful for transmit/receive fiber routing and ordered patching inside dense panels.

APC-Oriented Singlemode Link

The green APC format helps installers separate angled-polish singlemode ports from blue UPC ports during handoff and maintenance.

Flip-Style Port Protection

The flip style helps keep the adapter opening protected before patching. It also reduces the chance of leaving unused LC ports fully exposed.

No-Flange Panel Design

Without-flange mounting keeps the faceplate clean and compact, but it requires the correct cutout and locking structure from the panel supplier.

Ceramic Sleeve Alignment

The sleeve is selected for precise ferrule alignment, supporting stable insertion loss across repeated mating cycles.

Batch-Friendly Sourcing

For cabinet or panel projects, adapters can be specified by body style, sleeve, color, polish, flange type and packaging to reduce mixed-material risk

Installation Notes for Panels and Fiber Boxes

For this product, installation quality depends less on complicated tools and more on correct matching between the adapter body and the panel structure. Check the mechanical details before installing a full batch.

1. Confirm CutoutMatch the adapter body with the panel opening and retention design.
2. Check OrientationKeep APC ports facing the planned patch-cord direction and label side.
3. Inspect Port CleanlinessDo not remove protective caps earlier than needed.
4. Insert Connector StraightAvoid twisting the LC connector during mating.
5. Record Port MapDocument Tx/Rx or feeder/drop assignment after patching.
APC and UPC connectors should not be mixed. A green LC/APC port should be paired with LC/APC patch cords or pigtails specified for the same optical link.

Where to Use LC APC DX Flip Adapter

FTTH PON Distribution Panels

Used where LC/APC ports are required for passive optical links, splitter outputs, access node cross-connects or compact fiber distribution equipment.

ODF and Telecom Room Patching

Suitable for optical distribution frames and rack panels where stable, repeatable LC/APC connection points are required.

5G Fronthaul and Transport Cabinets

Can be used in protected cabinets where duplex singlemode patching supports radio access, transport or backhaul optical links.

Data Center and Equipment Interconnect

Useful for organized LC duplex patching between panels, transceiver areas and singlemode fiber trunk routes.

Panel Design and RFQ Checklist

When this adapter is purchased for a panel assembly, FDB, patch panel or ODF project, the RFQ should describe both the optical requirement and the mechanical requirement. This prevents wrong flange type, wrong color or wrong sleeve material from entering the batch.

RFQ Item Recommended Description Reason for Checking
Adapter Format LC APC DX Flip Adapter Separates this item from LC simplex, LC UPC and non-flip variants.
Panel Mounting Without flange Ensures the adapter matches the faceplate or cassette cutout.
Sleeve Ceramic alignment sleeve Confirms precision alignment material for singlemode application.
Color Green Maintains APC port identification across the whole panel.
Connector Side LC/APC to LC/APC Avoids confusion with hybrid adapters or wrong connector families.
Packaging Bulk bag / tray / individually protected as requested Protects flip covers and reduces contamination during production handling.
Inspection Requirement Visual inspection, sleeve condition, insertion loss sample test Improves batch acceptance before cabinet assembly.

Product Gallery

LC APC DX Flip Adapter front view with dust caps
LC APC duplex flip adapter side view green housing
LC APC DX flip adapter close-up front port view

Quotation Information Needed

To quote the right LC/APC duplex adapter for your project, share the adapter specification together with the panel or box usage. A small mechanical difference can affect whether the adapter fits the final assembly.

  • Product name or target URL
  • Required quantity and packaging method
  • LC/APC singlemode confirmation
  • Duplex body style confirmation
  • With flange or without flange
  • Panel cutout or drawing if available
  • Any sample inspection or test report requirement
  • Destination country and expected delivery schedule
Quotation Information Needed
 

FAQ

Q: What does DX mean in LC APC DX Flip Adapter?

A: DX usually refers to duplex. In this product, the adapter body is used for a paired LC connection rather than a single simplex LC port.

Q: Is this adapter for singlemode or multimode fiber?

A: This listed product is specified as a singlemode LC/APC adapter.

Q: Can I use LC/UPC connectors with this adapter?

A: No. This is an APC adapter. LC/APC and LC/UPC connectors should not be mixed because the end-face polish angles are different.

Q: Is this version with flange?

A: No. The product specification lists the mounting type as without flange, so the panel cutout and locking structure should be confirmed before ordering.

Q: What is the listed insertion loss?

A: The listed insertion loss is ≤0.2 dB.

Q: What should be checked before bulk purchase?

A: Confirm LC/APC interface, duplex body, no-flange mounting, ceramic sleeve, green color, packaging, panel fit and the required inspection method.


gloryoptic
Our Quality Promise

Comprehensive 3-Year Warranty

We confidently back all our products with a 3-year warranty. Our specific service policy is: within one year for quality issues, we take full responsibility for returns; within two years, for replacements; and within three years, for repairs.

Clear & Competitive MOQ

We welcome both trial and bulk orders. Our standard Minimum Order Quantity (MOQ) is 50 units. We also offer free samples for testing​ to help you evaluate our quality with confidence.

Fast & Reliable Logistics

We guarantee delivery within 10 days​ for standard items. Our logistics advantage includes cost-effective door-to-door service​ to simplify shipping for you.

Our Foundation

Backed by 18 years of experience​ since 2008, we control quality from our own factory, accept OEM/ODM​ requests, and maintain ready stock​ for wholesale. We focus on delivering the optimal balance of price and quality​ directly to end customers​ worldwide.

 

Your trust is our priority. Partner with us for dependable fiber optic solutions supported by clear promises.

Hot Tags: lc apc dx flip adapter, China lc apc dx flip adapter manufacturers, suppliers, factory, fiber optic installation, fiber optic jumpers, fiber optic port, lc to sc fiber cable, patch panel fiber optic, plc fiber

Send Inquiry