LC APC DX Internal Flip Adapter Without Flange

Send Inquiry
LC APC DX Internal Flip Adapter Without Flange
Details
Adapter Type: LC
Body Style: Duplex
Connector Polish Type: APC
Connector Fiber Mode: Singlemode
Insertion Loss: ≤0.2dB
Durability: >1000times
Mounting Type: Without Flange Aligment Sleeve Material: Ceramic
Color: Green RoHS Compliancy Status: Compliant
Category
Fiber Optic Adapter
Share to
Description

Product Role in a Fiber Panel

The LC APC Duplex Internal Flip Adapter without Flange is used to join two LC/APC singlemode connectors inside an optical distribution frame, fiber terminal box, patch panel or equipment cabinet. Its adapter sleeve keeps the two ferrules aligned so that the optical path remains stable after repeated patching.

The duplex form places two LC channels in one compact body. For panel designers, this helps increase port density while keeping transmit and receive paths arranged in a controlled way. The internal flip structure is useful when the panel layout requires defined A/B port orientation rather than a loose pair of simplex adapters.

Best-Fit Use

  • LC/APC singlemode jumper connection points
  • ODF, ODF sub-rack and patch panel assembly
  • FTTH, FTTx, CATV and video transmission networks
  • High-density optical cross-connect cabinets
  • Equipment ports where APC return loss control is required

Product Images

The images below show the LC/APC duplex internal flip adapter from different product angles and help buyers confirm housing shape, green APC identification and without-flange snap-in structure before quotation.

Technical Data

Product Name LC APC Duplex Internal Flip Adapter without Flange
Adapter Type LC
Body Style Duplex
Polish Type APC
Fiber Mode Singlemode
Insertion Loss ≤0.2 dB
Durability >1000 mating cycles
Mounting Type Without flange
Alignment Sleeve Ceramic
Color Green
RoHS Status Compliant
Working Temperature -40°C to +85°C
Storage Temperature -40°C to +85°C
The reference product data lists LC duplex, APC polish, singlemode operation, ceramic sleeve, green color and without-flange mounting. When ordering for a project, confirm the panel cut-out, clip direction and required package quantity before mass production.

Design Points for This Adapter

Internal Flip Orientation

The internal flip configuration helps panel builders manage duplex LC orientation when patch cord polarity needs to be kept predictable across multiple ports.

APC Singlemode Interface

The green APC format is selected for singlemode links where angled-polish connectors are used to help control back reflection in access, CATV and video networks.

Ceramic Sleeve Alignment

The ceramic alignment sleeve supports stable ferrule positioning, which is important for keeping insertion loss consistent after repeated plug-in operations.

No-Flange Panel Mounting

The without-flange body is suited to snap-in panel positions where the adapter is retained by the housing and clip structure rather than external screw ears.

Duplex LC Density

Two LC channels are arranged in one adapter footprint, making it useful for ODF trays, compact distribution boxes and crowded telecom equipment panels.

Project-Level Consistency

For batch orders, consistent color, sleeve type, polish type and panel fit help reduce installation mistakes and speed up field replacement.

Installation and Panel Assembly Notes

This adapter is normally installed before final jumper routing. A small assembly error can lead to reversed port orientation, tight cable bends or avoidable optical loss, so panel fit should be confirmed before batch production.

Check Cut-Out

Confirm the adapter opening, wall thickness and retention style of the panel, cassette or distribution box.

Confirm Orientation

Review A/B direction before inserting the adapter, especially when duplex polarity is documented in the as-built file.

Protect End Faces

Keep dust caps on until connector mating. Inspect and clean LC/APC connectors before final connection.

Verify Link

After jumper connection, record port ID, test insertion loss and update the port map for future maintenance.

Application Layer

FTTH / FTTx Access Points

Used in distribution nodes, terminal boxes and subscriber-side access panels where LC/APC singlemode patching is required.

CATV and Video Transmission

APC connector systems are common in video and RF overlay environments where return loss performance matters.

Telecom ODF and Cross-Connects

Suitable for central office frames, regional aggregation cabinets and equipment rooms that use high-density LC panels.

LAN / WAN Optical Links

Supports LC/APC singlemode patch cord connections between devices, shelves and passive fiber management modules.

Inspection Points Before Shipment

Check Item Why It Matters Recommended Confirmation
Adapter body and clip Ensures the adapter locks firmly into the intended panel position. Sample-fit the adapter in the actual panel or drawing-confirmed cut-out.
APC color and polish match Prevents mixing APC and UPC interfaces in singlemode systems. Confirm green body and LC/APC connector compatibility.
Ceramic sleeve condition A damaged or contaminated sleeve can affect connector alignment. Inspect sleeve position and keep caps installed until use.
Insertion loss batch data Provides acceptance evidence for project procurement and incoming QC. Request test data or agreed sampling inspection method.
Packaging method Protects adapters from dust and deformation during long-distance shipment. Confirm bag quantity, carton labeling and OEM packing requirements.

RFQ Information for Glory Optical

To avoid wrong adapter selection, send the basic optical and mechanical requirements together when requesting a quotation.

RFQ Item Example for This Product
Adapter Type LC
Port Style Duplex, internal flip structure
Polish / Fiber Mode APC, singlemode
Mounting Without flange, snap-in panel mounting
Sleeve Ceramic alignment sleeve
Color Green
Quantity Sample order, cabinet assembly batch or bulk project order
Packing Requirement Standard neutral packing or OEM label/carton requirement

FAQ

Q: What is an LC APC duplex internal flip adapter used for?

A: It is used to mate two LC/APC singlemode connector pairs in a duplex port while keeping a defined port orientation inside a panel, cassette, distribution frame or terminal box.

Q: Is this adapter for singlemode or multimode fiber?

A: This version is specified for singlemode fiber and APC-polished LC connectors.

Q: What does without flange mean?

A: Without flange means the adapter does not use external screw ears. It is normally held by the panel opening and snap-in retention structure.

Q: Why is the adapter green?

A: Green is commonly used to identify APC singlemode interfaces, helping installers avoid mixing APC and UPC connectors during field work.

Q: What information should be confirmed before mass order?

A: Confirm LC duplex format, APC polish, singlemode use, internal flip orientation, without-flange mounting, ceramic sleeve, color, quantity, packing method and panel cut-out compatibility.


gloryoptic
Our Quality Promise

Comprehensive 3-Year Warranty

We confidently back all our products with a 3-year warranty. Our specific service policy is: within one year for quality issues, we take full responsibility for returns; within two years, for replacements; and within three years, for repairs.

Clear & Competitive MOQ

We welcome both trial and bulk orders. Our standard Minimum Order Quantity (MOQ) is 50 units. We also offer free samples for testing​ to help you evaluate our quality with confidence.

Fast & Reliable Logistics

We guarantee delivery within 10 days​ for standard items. Our logistics advantage includes cost-effective door-to-door service​ to simplify shipping for you.

Our Foundation

Backed by 18 years of experience​ since 2008, we control quality from our own factory, accept OEM/ODM​ requests, and maintain ready stock​ for wholesale. We focus on delivering the optimal balance of price and quality​ directly to end customers​ worldwide.

 

Your trust is our priority. Partner with us for dependable fiber optic solutions supported by clear promises.

Hot Tags: lc apc dx internal flip adapter without flange, China lc apc dx internal flip adapter without flange manufacturers, suppliers, factory, a fiber optic cable, fiber optic installation, fiber optic jumpers, lc to sc fiber cable, optical connectors, patch panel fiber optic

Send Inquiry