Splice Closure for Optical Fiber Cable

Send Inquiry
Splice Closure for Optical Fiber Cable
Details
Item: Splice Closure For Optical Fiber Cable
Model: GL-GPJ09-9417-B
It is a multifunctional optical cable connection product, hinge structure, watertight and no screw design, open easily.
It can be pre-installed 16pcs Hardened SC Compatible adapters, easy to connect Corning devices. Apply to aerial mounting, manhole mounting, wall mounting and pole mounting.
Category
Fiber Optic Enclosure
Share to
Description
Product Overview

A splice closure and hardened drop-interface platform for outdoor fiber nodes

GL-G144 combines high-count fusion-splice storage with an optional pre-connectorized access arrangement. It supports distribution, bridging and branching at feeder-to-distribution or distribution-to-drop transition points, while keeping splice capacity separate from the number of external adapter positions.

Closed side view of GL-G144 fiber splice enclosure box with hinged housing and latches

Closed side view showing the housing, hinge line and closure latches.

Open GL-G144 fiber splice enclosure with splice trays and hardened SC APC adapter layout

Open internal structure with splice trays, fiber routing and connectorized positions.

Hardened connector ports and tethered dust caps on GL-G144 fiber splice enclosure box

External hardened interface detail with tethered protective caps.

 

Configuration boundary: 144 fibers refers to maximum fusion-splice capacity; up to 16 refers to hardened adapter positions. A connectorized build does not imply that every splice position or every adapter position is loaded.

 

Technical Selling Points

Core features of the GL-G144 fiber splice enclosure box

01

144-Fiber Fusion-Splice Capacity

The enclosure protects up to 144 fusion splices using 24-fiber tray organization described on the source page. This gives project planners a defined high-count splice ceiling while preserving tray-based routing for branch and bridge work. Confirm the final tray quantity and loaded capacity on the approved BOM before ordering.

02

Up to 16 Hardened SC/APC Interfaces

An optional connectorized arrangement supports up to 16 OptiTap SC/APC adapter positions. Compared with a splice-only closure, external hardened ports create a defined mating point for compatible pre-terminated drops. Buyers should confirm the exact hardened connector family, adapter count and port map; optical loss values are not published on the source page.

03

Six Cable Entries for Ø3–20 mm Cable

Three input and three output ports accept the listed 3–20 mm cable range, including loose-tube and skeleton cable constructions. Optional rubber seals are offered for Ø8–11, Ø10–16 and Ø18–20 mm ranges, allowing the entry seal to be matched to the project cable instead of treating one grommet as universal.

04

IP68 Hinged Mechanical Seal

The PP+GF housing uses a hinged lid, closure buckles and a silicone rubber body seal, with IP68 stated for the enclosure. The mechanical opening supports planned re-entry without heat-shrink replacement. IP68 must still be interpreted against agreed test depth and duration; it does not describe unlimited underwater operation.

05

Compact PP+GF Housing

At 340 × 180 × 140 mm and a listed unit weight of 3.0–3.5 kg, the enclosure combines a compact footprint with PP+GF construction. Pole, wall, pipe or duct, manhole and direct-buried placements are listed, helping engineers check available space and mounting access before releasing the installation drawing.

06

Project-Specific Mounting and Accessory BOM

Wall and aerial mounting kits are listed as on-demand accessories, while the packing schedule includes closure sealing parts, splice sleeves and routing consumables. Procurement teams can separate standard enclosure contents from mounting hardware and connector loading, reducing ambiguity between a bare closure, a splice-ready kit and a pre-connectorized terminal.

 

Product Configuration

Standard platform and order-dependent options

The source page identifies one product model, GL-G144. Capacity, adapter loading, cable seals and mounting hardware must be released as an order-specific configuration rather than inferred from the model name alone.

Confirmed platform data

  • GL-G144 fiber optic enclosure family
  • Maximum 144 fusion splices
  • Six cable ports: three input and three output
  • PP+GF housing with IP68 ingress rating
  • Distribution, bridging and branching connection modes

Selectable or on-demand items

  • Up to 16 OptiTap SC/APC adapter positions
  • Rubber seals for Ø8–11, Ø10–16 or Ø18–20 mm cable
  • Wall-mounting kit
  • Aerial-mounting kit
  • Project labeling, packaging and loaded assembly subject to drawing confirmation

 

Verified Product Data

GL-G144 fiber splice enclosure box technical specifications

The tables below use data stated on the original product page. Unpublished optical, environmental and mechanical values are intentionally excluded.

General Technical Specifications
Product model GL-G144
Product family Fiber Optic Enclosure / Fiber Splice Enclosure Box
Maximum fusion-splice capacity 144 fibers
Hardened adapter capacity Up to 16 positions, optional configuration
Connector interface stated OptiTap SC/APC adapter option
Cable entry count 6 total: 3 input and 3 output
Cable types stated Loose-tube cable and skeleton cable
Cable diameter range Ø3–20 mm
Enclosure material PP+GF
Enclosure dimensions 340 × 180 × 140 mm
Listed unit weight 3.0–3.5 kg
Ingress rating IP68
Sealing method Silicone rubber body seal with hinged lid and mechanical buckles
Mounting / placement stated Pole, wall, pipe or duct, manhole and direct burial; aerial kit available on demand
Connection modes stated Distribution, bridging and branching
Carton packing 6 sets per carton
Carton size 420 × 370 × 500 mm
Listed packing weight 22 kg; source page does not identify net or gross basis
Model and Capacity Table
Model Splice Capacity Adapter Positions Tray Reference Cable Ports Dimensions Unit Weight
GL-G144 Up to 144 fusion splices Up to 16 OptiTap SC/APC 24 fibers per tray stated; final tray quantity must follow approved BOM 6 (3 in / 3 out) 340 × 180 × 140 mm 3.0–3.5 kg
Optical data boundary: The original GL-G144 page does not publish connector insertion loss, return loss, splitter loss, wavelength, uniformity, PDL, directivity or fiber-standard values. These must be specified and documented for the selected loaded configuration; no values are inferred here.

 

Cable and Connector Compatibility

Match the cable entry and hardened interface before production

Cable Compatibility
Item Confirmed Data Procurement Check
Cable construction Loose-tube and skeleton cables Confirm sheath profile and internal strength-member arrangement
Overall cable OD Ø3–20 mm Provide measured OD, not nominal fiber count alone
Entry allocation 3 input / 3 output Release the route and branch map before assembly
Optional seal Ø8–11 mm On demand Match to actual cable sample or approved drawing
Optional seal Ø10–16 mm On demand Match to actual cable sample or approved drawing
Optional seal Ø18–20 mm On demand Match to actual cable sample or approved drawing

Internal adapter and fiber-routing detail. Confirm the hardened mating interface and factory-loaded port map for each project.

Connector Interface Check
Interface Element Source-Page Configuration What the Buyer Must Confirm
External hardened adapter Up to 16 OptiTap SC/APC positions Exact hardened connector family and mating drop assembly
Polish SC/APC stated Do not substitute standard SC/UPC or assume a standard indoor SC adapter fits the hardened port
Pre-termination Supported as an optional connectorized arrangement Loaded port quantity, internal pigtail routing, labels and factory test requirements
Optical performance Not published for GL-G144 Acceptance limits, test method and report format must be included in the RFQ

 

Network Applications

GL-G144 fiber splice enclosure box for FTTH and outdoor ODN routes

Use the enclosure where high-count splicing, branch routing and optional hardened subscriber or distribution interfaces must occupy the same protected field node.

FTTH Last-Mile Distribution with Hardened Drops

A splice-only closure forces crews to open the enclosure whenever a new pre-terminated drop is connected, while an unmatched terminal can leave feeder capacity and drop ports misaligned. GL-G144 combines up to 144 fusion splices with as many as 16 OptiTap SC/APC hardened adapter positions. It can sit at a pole, wall or manhole transition between distribution cable and compatible hardened drop assemblies. Before purchase, confirm the number of live ports, spare fibers, SC/APC hardened mating family, cable diameters, port labels and whether the shipment is unloaded, splice-ready or factory pre-terminated.

GPON or XGS-PON Feeder-to-Distribution Branching

Treating every branch enclosure as a splitter terminal can create an incorrect optical budget and confuse splice capacity with subscriber ports. GL-G144 provides distribution, bridging and branching functions with six cable entries and up to 144 fusion splices, making it suitable for feeder-to-distribution junctions in pole, duct or manhole sections of a passive ODN. It accepts the listed loose-tube or skeleton cables from 3 to 20 mm. If a PLC splitter is required, specify it separately: the source page gives no splitter ratio, package, loss or mounting data for this model.

Underground Handholes and Direct-Buried OSP Routes

An enclosure selected only by fiber count may fail at the cable entry when different sheath diameters share the same handhole. GL-G144 uses a silicone rubber body seal, mechanical buckles and an IP68-rated PP+GF housing, with cable support from 3 to 20 mm and optional seals for three OD bands. It can be placed in manholes or direct-buried routes where local engineering permits. Procurement should confirm measured cable OD, port allocation, groundwater conditions, planned re-entry and the IP test depth and duration required by the project; IP68 is not an unlimited-submersion statement.

Pole, Wall and Aerial OSP Distribution Nodes

Using the enclosure without the correct bracket or cable support can leave the field team improvising attachment hardware and strain relief. The 340 × 180 × 140 mm GL-G144 housing supports pole and wall placement, and the source page lists wall and aerial mounting kits on demand. Six cable ports accommodate feeder, distribution and branch routing, while hardened SC/APC positions can serve compatible pre-connectorized links. Before release, confirm the mounting kit, pole or messenger detail, cable route, port orientation, strength-member fixing method and environmental load requirements; those mechanical load values are not published for GL-G144.

 

Selection and Installation Guidance

Specify the field node, not just "one 144-fiber closure"

Selection sequence

  1. Define the network role: feeder splice, distribution branch or hardened drop access.
  2. Calculate working and reserved fusion splices without treating adapter count as fiber capacity.
  3. Map all six cable entries and provide the construction and measured OD of each cable.
  4. Confirm whether hardened outputs are required and identify the exact mating connector family.
  5. Choose pole, wall, aerial, duct, manhole or direct-buried installation and specify the required kit.
  6. Release an approved tray layout, port map, label schedule and packing BOM before batch production.

Site and acceptance checks

  • Verify cable seals against actual cable OD before closing the housing.
  • Maintain the project-specified fiber bend radius; GL-G144 source data does not publish a numeric minimum.
  • Clean and inspect every SC/APC end face before mating a connectorized port.
  • Record splice allocation, adapter port ID and cable route for later re-entry.
  • Agree IP, optical and mechanical acceptance conditions before shipment and field commissioning.
Source-page BOM check: The capacity narrative references six 24-fiber trays, while the accessory schedule lists four splice trays. For a 144-splice configuration, tray quantity and per-tray capacity must be reconciled on the quotation, drawing and final packing list.

 

OEM and Project Procurement

Ordering configuration for a custom GL-G144 enclosure

Send enough information to distinguish a bare housing, a splice-ready closure and a loaded pre-connectorized fiber splice enclosure box.

Ordering Configuration
RFQ Item Confirmed Range or Option Information to Supply
Model GL-G144 Order quantity and target project
Splice capacity Up to 144 Working fibers, reserve fibers, tray count and splice map
Hardened ports Up to 16 OptiTap SC/APC positions Loaded quantity, exact mating family, port map and dust-cap requirement
Cable entries 6 total, 3 in / 3 out Entry assignment, cable construction and measured OD
Rubber seal option Ø8–11, Ø10–16 or Ø18–20 mm Seal required for each occupied entry
Mounting Pole, wall, pipe/duct, manhole, direct burial; aerial or wall kit on demand Site method, bracket or messenger requirement and installation drawing
Factory loading Connectorized configuration available Pigtail or cable assembly details, internal routing and test acceptance
OEM presentation Company-supported project option Logo, labels, language, barcode, carton marks and packaging artwork
Documentation Depends on order configuration Drawing, datasheet, applicable test report, packing photos and label schedule
Source-Page Accessory Schedule
Item Description Listed Quantity Order Status
1 Box body 1 set Listed accessory
2 Body sealing ring 1 set Listed accessory
3 Splice tray 4 pcs in accessory schedule Reconcile with required 144-splice tray BOM
4 Wall-mounting kit 1 set On demand
5 Aerial-mounting kit 1 set On demand
6 Cable cleaning tissue 1 bag Listed accessory
7 Silicone grease 1 bag Listed accessory
8 Splice sleeve 144 pcs Listed accessory
9 Insulation tape 1 roll Listed accessory
10 EVA protective tube 1 m Listed accessory
11 Nylon tie 20 pcs Listed accessory
12 Installation manual 1 set Listed accessory
13 Unvulcanized sealing tape 1 pc Listed accessory
14 Drying agent 1 bag Listed accessory

 

Company Background

Why Glory Optical for GL-G144 project supply

Glory Optical Communication is a Ningbo-based passive fiber optic infrastructure manufacturer founded in 2008. Its current company page describes more than 300 passive optical products and supply to over 50 countries, covering fiber boxes, splice closures, PLC splitters, FTTH cables, adapters, patch cords and MTP/MPO assemblies.

2008 Founded in Ningbo, China
300+ Passive optical products stated
50+ Countries served as stated

Enclosure manufacturing and assembly

The company page describes mold and CNC capability for enclosure geometry, gasket position, cable-entry cutouts and structural details. Assembly support covers fiber boxes, splice trays, adapters, pigtails and cable-management parts against a confirmed drawing and port map-directly relevant to the GL-G144 housing and loaded connector configuration.

Specification review before quotation

Technical review can cover fiber count, adapter type, splice-tray capacity, cable diameter, cable entry, mounting method, IP requirement, labels and port maps. For GL-G144, that review should also resolve the tray-BOM discrepancy and identify whether the order is splice-only or includes hardened SC/APC ports.

Connectorized product testing support

Glory Optical states that connectorized products and cable assemblies can be checked for insertion loss, return loss and connector end-face condition where applicable. Because GL-G144 does not publish numeric optical limits, the buyer should place required thresholds, sampling level and report format in the approved order specification.

OEM release and repeat-order control

OEM/ODM support can include housing structure, port layout, cable entry, color, logo, labels, packaging, adapter configuration and splice-tray layout. The stated project workflow covers drawing or photo review, specification confirmation, sample planning, testing, packing and batch supply, with final scope tied to the approved order.

 

 

Project RFQ

Configure the GL-G144 fiber splice enclosure box for your route

Send the required splice count, cable construction and OD, six-port entry map, hardened SC/APC port quantity, mounting method, tray layout, labels, testing requirements and order quantity. Glory Optical can then review the enclosure BOM before quotation and sample confirmation.

Hot Tags: splice closure for optical fiber cable, China splice closure for optical fiber cable manufacturers, suppliers, factory, fiber box, Splice Closure For Optical Fiber Cable, fiber in a box, fiber optic enclosure, fiber splice enclosure box, Joint Closure Dome

Send Inquiry