Model: SC Adapter Transparent With Flange
Adapter Type: SC
Body Style: Simplex Connector Polish Type: PC
Connector Fiber Mode: Singlemode
Insertion Loss: ≤0.2dB
Durability: >1000times
Mounting Type: Without Flange
Aligment Sleeve Material: Ceramic
Color: Transparent
RoHS Compliancy Status: Compliant
Category
Fiber Optic Adapter
Share to
Description

What Makes This Version Different

No-Flange Body

The adapter is selected for panels or boxes where side flanges and screws are not required. This helps keep the front face compact.

Transparent Housing

The clear body makes the adapter easy to distinguish from the common blue, green or beige adapter colors used in mixed patching areas.

SC Simplex Channel

One adapter position supports one SC-to-SC fiber connection, suitable for subscriber lines, test ports or spare panel interfaces.

Ceramic Sleeve

The ceramic sleeve is used to keep the connector ferrules aligned during repeated insertions and removals.

Confirmed Product Data

Product Name SC Adapter Without Flange
Model / Description SC Adapter Transparent Without Flange
Adapter Type SC
Body Style Simplex
Connector Polish Type PC
Fiber Mode Singlemode
Insertion Loss ≤0.2 dB
Durability >1000 times
Mounting Type Without flange
Alignment Sleeve Material Ceramic
Color Transparent
RoHS Status Compliant
The source product page title and mounting field indicate "without flange." If an RFQ form uses a legacy model wording that mentions flange, confirm the final drawing or sample photo before mass production.

Panel Fit and Installation Logic

A no-flange SC adapter should not be treated the same way as a screw-fixed adapter. The most important confirmation is whether the adapter body locks correctly into the existing cutout or adapter holder. For replacement projects, check the original panel opening, latch position and front clearance before ordering a bulk batch.

Step 01Confirm SC simplex port count and whether the panel is designed for no-flange adapters.
Step 02Match PC singlemode patch cords on both sides. Do not mix APC connectors with PC/UPC ports.
Step 03Clean both connector end faces before insertion to avoid carrying dust into the sleeve area.
Step 04Insert the adapter from the correct side and verify that the latch sits firmly in the panel.
Step 05After patching, record the port number and run optical power or link-loss verification when required.
Use It Where the Panel Provides the Retention

Use It Where the Panel Provides the Retention

Without-flange adapters rely on the panel slot, clip or holder for mechanical retention. They are suitable when the enclosure design already controls adapter position and does not need extra screws on the adapter face.

  • Compact ODF trays and patch panels
  • Fiber terminal boxes with molded adapter slots
  • Subscriber access panels and test positions
  • Internal modules where screw flanges would block the layout

Specification Range for SC Adapter Projects

The product family specification allows the SC adapter line to support different polish and fiber-mode combinations. For this SKU, use the transparent singlemode PC without-flange configuration unless the project drawing calls for another version.

Parameter SC Adapter Family Reference What to Confirm for This SKU
Polish Options PC / UPC / APC depending on ordered model This page lists PC. Keep connector polish matched across both sides.
Fiber Mode Singlemode and multimode versions may be available This page lists singlemode.
Insertion Loss ≤0.2 dB for listed singlemode entries; ≤0.3 dB shown for multimode reference Use ≤0.2 dB as the purchasing checkpoint for this singlemode SKU.
Repeatability / Alternating Loss ≤0.2 dB Check random samples after repeated mating if the adapter is used in test panels.
Durability 1000 insertion cycles with change less than 0.2 dB Useful for maintenance ports and frequently accessed cabinets.
Working Temperature -40°C to +85°C Suitable for equipment rooms, outdoor boxes and cabinet environments when the enclosure is properly selected.
Storage Temperature -40°C to +85°C Keep adapters clean and capped during storage before assembly.

Application Layer

ODF and Cross-Connection Frames

Used as an SC port in distribution frames where a clean, simple one-fiber interface is needed for jumper management or subscriber routing.

FTTH Terminal Boxes

Fits indoor or outdoor terminal boxes when the molded slot is already made for no-flange SC adapters and the project uses PC singlemode patching.

Equipment-Side Patch Panels

Can be used in access equipment cabinets, passive panels and test benches where compact adapter mounting is more important than screw mounting.

Fiber optic adapter and connector application detail
Different fiber optic adapters for panel and cabinet assembly projects

Procurement Checklist for Bulk Orders

For a small component like an SC adapter, many quality issues come from unclear configuration rather than from the adapter name itself. Use the checklist below when sending an inquiry or confirming a sample.

RFQ Item Recommended Confirmation
Adapter Format SC simplex, not duplex and not LC/FC/ST.
Mounting Without flange. Share panel photos or cutout drawings for fit confirmation.
Polish / Mode PC singlemode as listed on this page. Confirm if UPC or APC is required instead.
Sleeve Ceramic sleeve for stable ferrule alignment.
Color Transparent housing. Confirm if your project uses a strict color-coding rule.
Testing Requirement Insertion loss ≤0.2 dB; random batch inspection can be requested for project orders.
Packaging Individual or bulk packaging depending on assembly-line use and warehouse handling.

Handling and Acceptance Notes

Before Installation

Check the adapter body for cracks, verify the sleeve is clean, and keep dust caps installed until the connector is ready to mate.

During Assembly

Do not force the adapter into an incompatible panel slot. A loose fit may create unstable retention; an overly tight fit may damage the transparent housing.

After Patching

Confirm the SC connector latch is fully seated and the patch cord is not pulling against the adapter at a sharp angle.

For Maintenance

If the port is opened repeatedly, inspect for dust and sleeve contamination before blaming the fiber cable or transceiver.

FAQ

Is this adapter screw-mounted?

No. The listed mounting type is without flange, so it should be used with a panel or holder designed for no-flange adapter retention.

What connector should be used with it?

Use compatible SC connectors. This product page lists a simplex SC adapter for singlemode PC connector mating.

Why is the housing transparent?

The transparent body helps distinguish this model from colored SC adapters and can be useful in custom panel assemblies where the adapter color is part of the BOM confirmation.

Can it replace a flanged SC adapter?

Only if the panel or adapter holder is designed for no-flange mounting. A screw-fixed panel may not hold this version correctly without changing the hardware.

What should be checked before mass production?

Confirm SC simplex format, PC singlemode polish, no-flange mounting, transparent color, ceramic sleeve and insertion-loss requirement.


gloryoptic
Our Quality Promise

Comprehensive 3-Year Warranty

We confidently back all our products with a 3-year warranty. Our specific service policy is: within one year for quality issues, we take full responsibility for returns; within two years, for replacements; and within three years, for repairs.

Clear & Competitive MOQ

We welcome both trial and bulk orders. Our standard Minimum Order Quantity (MOQ) is 50 units. We also offer free samples for testing​ to help you evaluate our quality with confidence.

Fast & Reliable Logistics

We guarantee delivery within 10 days​ for standard items. Our logistics advantage includes cost-effective door-to-door service​ to simplify shipping for you.

Our Foundation

Backed by 18 years of experience​ since 2008, we control quality from our own factory, accept OEM/ODM​ requests, and maintain ready stock​ for wholesale. We focus on delivering the optimal balance of price and quality​ directly to end customers​ worldwide.

 

Your trust is our priority. Partner with us for dependable fiber optic solutions supported by clear promises.

Hot Tags: sc adapter without flange, China sc adapter without flange manufacturers, suppliers, factory, a fiber optic cable, fiber optic installation, fiber optic jumpers, fiber optic port, lc to sc fiber cable, patch panel fiber optic

Send Inquiry