Optical Fiber Distribution Box Overview
Network Function
The GL-16Q is positioned at an outdoor FTTx distribution point where incoming optical cable is fixed, fibers are spliced and stored, optional PLC splitting is integrated, and outgoing subscriber or branch cables leave the enclosure. The published data distinguishes a maximum of 108 fusion splices from the 16 household cable exits; these values must not be treated as the same capacity.
Product photography shows a separate adapter field and stacked splice trays. The text does not confirm a standard connector or polish type, so the loaded adapter interface should be defined in the project BOM rather than inferred from image color alone.
Closed Outdoor Enclosure
Black enclosure with external cable-entry and subscriber-exit field. Final resin version must be confirmed because the source page contains PP and ABS references.
Product Selling Points
108-Splice Tray Capacity
The published maximum fusion capacity is 108, giving the enclosure room for feeder, branch, and distribution-side splice organization within stacked trays. This matters when a 16-exit access point must retain spare fibers or support later branch changes instead of forcing every splice into a compact single-layer tray.
Separated Feeder, Branch and Drop Openings
One oval optical-cable entry and two branch cable entries are separated from 16 household cable exits. Compared with an enclosure that uses a single mixed gland field, this layout helps procurement teams map feeder, branch, and subscriber routes before installation and reduces the chance of ordering the wrong number or type of cable openings.
Micro PLC Splitter Accommodation
The tray system accommodates micro PLC splitter ratios of 1×2, 1×4, 1×8, and 1×16. The page specifies 60 × 7 × 4 mm packages for the smaller ratios and 60 × 12 × 4 mm for 1×16, so splitter dimensions and compatible tray versions can be confirmed before loading.
Published Outdoor Environmental Range
The detailed environmental table specifies IP68 protection, −40°C to +65°C operation, −5°C to +40°C installation, and −40°C to +65°C storage. These values support outdoor FTTx planning, but IP68 should not be interpreted as approval for unlimited submersion; handhole conditions still require project-specific sealing and acceptance criteria.
Defined Feeder and Drop Cable Sizes
The main cable entry accepts cable up to Ø18 mm, while subscriber outlets are specified for 2 × 3 mm flat cable through Ø7 mm round cable. This defined range lets buyers check feeder and drop profiles against the enclosure before production instead of relying on nominal port count alone.
Three Outdoor Mounting Methods
The 378 × 255 × 116 mm enclosure supports wall, pole, and aerial mounting, with published installation-hole positions of 215 × 266 × 239 mm. Using the mounting drawing and accessory list at RFQ stage helps contractors verify site fit, pole hardware, and messenger attachment before the box reaches the field.
GL-16Q Configuration and Internal Structure
The original page publishes one model, GL-16Q, with optional micro PLC splitter ratios. It does not publish separate branch, TAP, MTC, MTS, or MTT model families for this enclosure, so those series should not be merged into the GL-16Q specification.
GL-16Q Optical Fiber Distribution Box Technical Specifications
Values below are reorganized from the current Glory Optical GL-16Q product page. Conflicting source values are marked rather than silently reconciled.
General Technical Specifications
| Item | Published Specification | Procurement Note |
|---|---|---|
| Product model | GL-16Q | Use the model together with an approved drawing and port map. |
| Product category | Optical fiber distribution box / fiber optic termination box | Outdoor FTTx distribution, splicing, storage and optional splitting. |
| Application | FTTx | Network node and loaded configuration must be defined by project. |
| External dimensions | 378 × 255 × 116 mm (A × B × C) | Check available wall, pole or aerial mounting space. |
| Installation hole positions | 215 × 266 × 239 mm (D × E × F) | Confirm against the latest mechanical drawing. |
| Maximum fusion capacity | 108 | This is splice capacity, not subscriber port count. |
| Cable openings | 1 oval optical-cable entry; 2 branch entries; 16 household cable exits | Confirm cable direction and sealing parts in the BOM. |
| Maximum incoming cable diameter | Ø18 mm | Published as the largest cable diameter. |
| Subscriber outlet cable size | 2 × 3 mm flat cable to Ø7 mm round cable | Confirm actual drop-cable profile and jacket tolerance. |
| Housing color | Black | Original page states color is customizable. |
| Housing material | PP in detailed description; ABS in page summary | Conflicting source values-material must be fixed in the approved order specification. |
| IP protection level | IP68 | Does not by itself define unlimited underwater operation. |
| Flammability | HB, conventional | Original page states other requirements can be customized; acceptance standard must be specified. |
| Neutral salt spray test | 48 hours | Published test duration; affected hardware and method are not stated. |
| Mounting method | Wall-mounted, pole-mounted, aerial-mounted | Confirm mounting kit and site hardware. |
Environmental Specifications
| Item | Detailed Table Value | Source-Control Note |
|---|---|---|
| Operating temperature | −40°C to +65°C | The page summary separately lists −25°C to +60°C; confirm approved version. |
| Installation temperature | −5°C to +40°C | Do not substitute the operating range for installation conditions. |
| Storage temperature | −40°C to +65°C | Published in the environmental table. |
| Atmospheric pressure | 70 to 106 kPa | Published environmental value. |
| Relative humidity | ≤93% at +40°C | Published environmental value. |
Model and Capacity Table
| Model | Subscriber Cable Exits | Maximum Fusion Splices | Cable Entries | Dimensions | Mounting |
|---|---|---|---|---|---|
| GL-16Q | 16 household exits | 108 | 1 oval + 2 branch entries | 378 × 255 × 116 mm | Wall / pole / aerial |
Micro PLC Splitter Configuration Table
| Split Ratio | Published Package Size | Compatible Tray Reference | Quantity per Tray |
|---|---|---|---|
| 1×2 | 60 × 7 × 4 mm | Type A or Type E splicing tray | 1 piece |
| 1×4 | 60 × 7 × 4 mm | Type A or Type E splicing tray | 1 piece |
| 1×8 | 60 × 7 × 4 mm | Type A or Type E splicing tray | 1 piece |
| 1×16 | 60 × 12 × 4 mm | Type A-1 or Type E-1 splicing tray | 1 piece |
Cable and Connector Compatibility
| Interface Area | Published or Visible Information | Required Confirmation |
|---|---|---|
| Main incoming cable | Maximum outside diameter Ø18 mm | Cable construction, strength-member fixing and gland parts. |
| Branch cable entries | 2 branch optical-cable entries | Individual branch diameters and sealing components. |
| Subscriber drop exits | 16 exits; 2 × 3 mm flat cable through Ø7 mm round cable | Actual flat/round drop profile and quantity used. |
| Adapter field | SC-format green adapters are visible in current product photography | Standard adapter quantity, connector interface and polish type are not defined in the text. |
Optical Fiber Distribution Box for FTTH and Outdoor FTTx Networks
GL-16Q Optical Fiber Distribution Box for FTTH Last-Mile Distribution
Using a small indoor termination box at an outdoor last-mile split point can leave too little space for feeder entry, splitter routing, splice storage, and subscriber drop exits. The GL-16Q combines up to 108 fusion splices, micro PLC splitter accommodation, and 16 household cable exits in one IP68 enclosure. It is installed between the feeder or distribution cable and outgoing FTTH drops in GPON or other PON access networks. Before procurement, confirm the required splitter ratio, tray type, populated adapter interface, feeder diameter, flat or round drop-cable profile, and whether the box will be supplied loaded or prepared for field assembly.
Pole-Mounted and Aerial Outdoor Fiber Distribution
Pole and aerial routes often fail at the enclosure interface when the mounting method, cable entry size, or drop-cable sealing arrangement is selected after the hardware has been ordered. The GL-16Q provides wall, pole, and aerial mounting options, one oval cable entry, two branch entries, and 16 subscriber cable exits. It can be positioned on distribution poles or messenger-supported routes where feeder and branch cables are reorganized before the drop section. Buyers should confirm pole diameter or aerial hardware, feeder cable outside diameter, branch-cable count, outlet profile, splice-tray arrangement, and the accessories included with the shipment.
MDU, Campus and Enterprise FTTx Distribution Points
A box chosen only by adapter count can create congestion in MDU, campus, or enterprise access networks when the design also requires high splice storage and integrated splitting. The GL-16Q separates the external cable-entry field, adapter area, and stacked splice trays, while the published maximum fusion capacity reaches 108. It is installed at a building exterior, shared telecom zone, or campus distribution point feeding multiple premises or network branches. The project BOM should identify the number of active subscriber exits, splitter ratio, connector and polish type, fiber routing plan, cable diameters, mounting surface, and labeling scheme before sample approval.
OEM Optical Fiber Distribution Box Procurement
Project-based sourcing becomes risky when a buyer treats color, material, flame rating, splitter format, and packaging as interchangeable options. The GL-16Q page lists black as the standard color, HB as the conventional flammability level, several micro PLC ratios, and customizable items, while its page summary and detailed specification contain conflicting material and temperature data. For OEM or repeat-order programs, use an approved drawing and sample to lock the enclosure resin, tray version, adapter population, splitter size, cable entries, labels, logo, mounting accessories, and packing. The final purchase specification should override informal page summaries and remain attached to every production order.
Installation and GL-16Q Selection Guidance
Published Installation Methods
Wall mounting: the original instructions call for four drilled holes, Ø7.5 × 40 mm expansion plugs, and screws aligned to the enclosure mounting positions.
Pole mounting: a hoop ring passes through the back-plate slot and is fixed around the telecom pole.
Aerial mounting: enclosure hardware is attached to the supporting wire and bolted to prevent the box from falling.
Wall, Pole and Aerial Mounting
The source image illustrates the three published installation methods. Site-specific hardware dimensions still need project confirmation.
Project Procurement Checklist
| Confirm Before Quotation | Why It Matters for the GL-16Q |
|---|---|
| Housing material and temperature version | The source page contains PP/ABS and temperature-range conflicts. |
| Required splice count | 108 is the maximum fusion capacity; actual tray loading and reserve fibers should be mapped. |
| Active subscriber exits | Do not confuse 16 cable exits with splice capacity or splitter output count. |
| PLC splitter ratio and package | 1×2 to 1×8 and 1×16 use different published package sizes and tray references. |
| Adapter and connector configuration | The text does not define the standard connector type, polish, loaded quantity, or optical loss. |
| Feeder, branch and drop cable dimensions | Check Ø18 mm maximum input and 2 × 3 mm to Ø7 mm outlet range against actual cables. |
| Mounting kit | Wall, pole and aerial methods require different hardware and site dimensions. |
| Handhole or flood-prone use | IP68 is not a substitute for defining immersion duration, water pressure, closure position and acceptance testing. |
| Drawing, port map and labels | These documents control repeat-order consistency and field identification. |
OEM and Project Ordering Configuration
Glory Optical's official company page states that project review can cover port count, fiber count, splitter ratio, loaded or unloaded box requirement, adapter type, splice-tray capacity, cable diameter, cable entry, mounting method, IP rating, labeling and port map. For the GL-16Q, the following fields should be fixed in the RFQ and approved sample.
| Ordering Field | Published Standard / Available Basis | RFQ Entry |
|---|---|---|
| Model | GL-16Q | Confirm exact drawing revision. |
| Housing material | Conflicting PP and ABS references | Select and approve one resin version. |
| Color | Black; customization referenced | State required color and approval method. |
| Splitter | Micro PLC 1×2 / 1×4 / 1×8 / 1×16 | State ratio, package, fiber type, lead length and connectorization. |
| Adapter field | SC-format green adapters visible in photography | State adapter quantity, SC/other interface, APC/UPC polish and loaded/unloaded status. |
| Cable entries | 1 oval + 2 branch + 16 subscriber exits | State every cable outside diameter and route. |
| Mounting accessories | Wall / pole / aerial methods published | List back plate, clamps, hoop, screws and messenger hardware required. |
| Flammability | HB conventional; customization referenced | State required material test and acceptance document. |
| Branding and packaging | OEM/ODM labeling, logo and packaging support stated by Glory Optical | Attach artwork, carton mark, label map and packing specification. |
| Documentation | Drawings, test reports, labels and packing photos may be requested depending on product and order | List required documents before quotation. |
Why Glory Optical for GL-16Q Project Supply
Glory Optical Communication is a Ningbo-based passive fiber optic manufacturer founded in 2008. Its official company page describes a 20,000 m² manufacturing facility with R&D, molding, assembly and testing functions, more than 300 passive optical products, supply to 50+ countries, and OEM/ODM project support.
Housing Molding and Enclosure Assembly
Tooling, mold development and enclosure assembly can be used to control housing geometry, gasket position, cable-entry cutouts, splice-tray layout and adapter placement. For GL-16Q repeat orders, these details should be locked by drawing and approved sample.
PLC Splitter and Internal BOM Integration
Glory Optical manufactures PLC splitters and assembles fiber boxes, adapters, pigtails, trays and cable-management parts. This allows a GL-16Q project BOM to define splitter ratio, tray version, adapter field and cable routing before batch production.
Optical and Assembly Checks Where Applicable
The company states that connectorized products and cable assemblies can be checked for insertion loss, return loss and connector end-face condition where applicable. Test limits for a loaded GL-16Q must still be written into the order because the product page publishes no optical loss values.
RFQ, Sample and Batch-Supply Control
The published project workflow covers drawing or photo review, specification confirmation, sample planning, testing, packing and batch supply. Buyers can use this sequence to close the current material and temperature conflicts before approving GL-16Q production.
Hot Tags: optical fiber distribution box, China optical fiber distribution box manufacturers, suppliers, factory, Outdoor Fiber Optic Junction Box, Nid Box, fiber optic box outdoor, Optical Fiber Distribution Box, fiber outlet box, box fiber